White Rodgers 1F83-0422 specifications Installer/Configuration Menu

Models: 1F83-0422

1 8
Download 8 pages 51.24 Kb
Page 4
Image 4
INSTALLER/CONFIGURATION MENU

INSTALLER/CONFIGURATION MENU

Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the

next menu item. Press Manual backgroundManual backgroundManual background or Manual backgroundManual backgroundManual background to change a menu item. Shaded items available on 1F85 model only.

INSTALLER/CONFIGURATION MENU

MENU

 

 

PRESS

DISPLAYED

Press

 

 

or

 

 

to

 

 

 

 

 

 

 

 

REF.

HP

SS

BUTTON

(FACTORY DEFAULT)

select from listed options

COMMENTS

1

1

1

MENU

(MS 2)

HP 1, SS 1

 

Selects Multi-Stage (MS 2 No Heat Pump),

 

 

 

 

 

 

 

 

 

 

 

 

Heat Pump 1 (HP 1, 1 compressor),

 

 

 

 

 

 

 

 

 

 

 

 

or Single Stage (SS 1)

2

2

2

MENU

(GAS) for SS or MS

 

 

ELE

 

GAS setting: furnace controls the blower

 

 

 

 

(ELE) for HP

 

 

 

 

 

 

 

ELE setting: thermostat controls the blower

3

3

3

MENU

CS (0)

1, 2, 4, 5, 6

 

 

Selects Cool Savings

 

 

 

 

(Disabled)

 

 

 

 

 

 

 

Value 1 (low) to 6 (high), Value 0 Disables Featrue

4

4

4

MENU

E (On)

 

 

OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

 

 

 

 

On or OFF. 1F85 only

5

5

MENU

CR Heat (ME)

 

SL, FA

 

Adjustable Anticipation:

 

 

 

 

 

 

 

 

 

 

 

 

Selects heating cycle rate for MS or SS

6

5

MENU

CR Heat Pump

 

SL, FA

 

Adjustable Anticipation (Heat Pump) (only

 

 

 

 

(ME)

 

 

 

 

 

 

 

when heat pump selected in #1)

7

6

6

MENU

CR Cool (ME)

 

SL, FA

 

Adjustable Anticipation:

 

 

 

 

or

 

 

 

 

 

 

 

Selects the cycle rate for cooling (only when

 

 

 

 

CR Emer (FA)

 

 

SL

 

MS 2 or SS 1 is selected in item 1.) or

 

 

 

 

 

 

 

 

 

 

 

 

Selects the cycle rate for Emergency mode

 

 

 

 

 

 

 

 

 

 

 

 

and Auxiliary stage if Heat Pump is selected

 

 

 

 

 

 

 

 

 

 

 

 

in item 1.

8

7

7

MENU

CL (OFF)

 

CL On

 

Compressor Lockout Time

9

8

8

MENU

Heat Auto

Heat Cool Off,

 

System Mode Configuration

 

 

 

 

 

Heat Off with Fan icon,

with Automatic Changeover capability

 

 

 

 

Cool Off

Heat Off without Fan icon

 

 

 

 

 

 

Cool Off, Auto Off

 

10

9

9

MENU

dL (On)

 

dL OFF

 

Selects Display Light On or OFF

11

10

10

MENU

0

1 HI, 2 HI, 3 HI, 4 HI,

Adjustable Ambient Temperature Display

 

 

 

 

(current temperature)

1 LO, 2 LO, 3 LO, 4 LO

 

12

11

11

MENU

°F

 

 

°C

 

Selects Fahrenheit/Celcius Temperature Display

13

12

12

MENU

L Heat

L 62 to L 89

 

Selects Limited HEAT Range

 

 

 

 

(90)

 

 

 

 

 

 

 

 

14

13

13

MENU

L Cool

L 46 to L 82

 

Selects Limited COOL Range

 

 

 

 

(45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

14

14

MENU

P3

 

P0, P2

 

Defaults for 5-1-1 programming (P3) but non-

 

 

 

 

 

 

 

 

 

 

 

 

programmable (PO) or 5-2 programming (P2)

 

 

 

 

 

 

 

 

 

 

 

 

is available on most models. 1F85 only

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

15

MENU

Heat AS (On)

 

 

OFF

 

Automatic Schedule for heat mode. 1F85 only.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Cool only system.

17

16

16

MENU

Cool AS (On)

 

 

OFF

 

Automatic Schedule for cool mode. 1F85 only.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Heat only system.

18

17

MENU

Heat FA (On)

 

 

OFF

 

Fast Heat option may be disabled by

 

 

 

 

 

 

 

 

 

 

 

 

selecting OFF. NA to SS config.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Cool only system.

19

18

MENU

Cool FA (On)

 

 

OFF

 

Fast Cool option may be disabled by

 

 

 

 

 

 

 

 

 

 

 

 

selecting OFF. NA to SS config.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Heat only system.

20

19

17

MENU

dS (On)

 

 

OFF

 

Selects Automatic daylight Savings Time option

 

 

 

 

 

 

 

 

 

 

 

 

On or OFF. 1F85 only

21

20

18

MENU

Change Filter (OFF)

 

 

On

 

Selects Filter Change-out Indicator On or OFF.

 

 

 

MENU

Change Filter (200 h)

25-1975 h

 

Change Filter time in 25 hour increments. This

 

 

 

 

 

 

 

 

 

 

 

 

menu only appears if On is selected in above.

22

21

19

MENU

Cool On (o)

Heat On (b)

 

Selects operation of the reversing valve terminal

 

 

 

 

 

 

 

 

 

 

 

 

(O/B) output as an O or B terminal.

 

22

20

RUN

 

 

 

 

 

 

 

 

Retuns to Normal Operation

 

 

 

SCHED

 

 

 

 

 

 

 

 

 

4

Page 4
Image 4
White Rodgers 1F83-0422 specifications Installer/Configuration Menu