![](/images/new-backgrounds/1052334/5233411x1.webp)
INSTALLER/CONFIGURATION MENU
With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show
item #1 in the table below. Press Menu button to advance to the next menu item. Press or
to change an item option.
INSTALLER/CONFIGURATION MENU
MENU |
|
| PRESS | DISPLAYED | Press |
|
| or |
|
| to |
|
|
|
|
|
|
|
| ||||||
REF. | HP | SS | BUTTON | (FACTORY DEFAULT) | select from listed options | COMMENTS | ||||||
1 | 1 | 1 | MENU | (MS 2) | HP 1, HP 2, SS 1 | Selects | ||||||
|
|
|
|
|
|
|
|
|
|
|
| Heat Pump 1 (HP 1, 1 compressor), |
|
|
|
|
|
|
|
|
|
|
|
| or Single Stage (SS 1), Heat Pump 2 (HP 2, 2 |
|
|
|
|
|
|
|
|
|
|
|
| compressor or 2 speed compressor) |
2 | 2 | 2 | MENU | (GAS) for SS or MS |
|
| ELE |
| GAS setting: furnace controls the blower | |||
|
|
|
| (ELE) for HP |
|
|
|
|
|
|
| ELE setting: thermostat controls the blower |
3 | 3 | 3 | MENU | CS (0) | 1, 2, 3, 4, 5, 6 |
| Selects Cool Savings | |||||
|
|
|
| (Disabled) |
|
|
|
|
|
|
| Value 1 (low) to 6 (high), Value 0 Disables Feature |
4 | 4 | 4 | MENU | E (On) |
|
| OFF |
| Selects Energy Management Recovery (EMR) | |||
|
|
|
|
|
|
|
|
|
|
|
| On or OFF. |
5 | – | 5 | MENU | CR Heat (ME) |
| SL, FA |
| Adjustable Anticipation: | ||||
|
|
|
|
|
|
|
|
|
|
|
| Selects heating cycle rate for MS or SS |
6 | 5 | – | MENU | CR Heat Pump |
| SL, FA |
| Adjustable Anticipation (Heat Pump) (only | ||||
|
|
|
| (ME) |
|
|
|
|
|
|
| when heat pump selected in #1) |
7 | 6 | 6 | MENU | CR Cool (ME) |
| SL, FA |
| Adjustable Anticipation: Selects the cycle rate for | ||||
|
|
|
| or |
|
|
|
|
|
|
| cooling (only when MS 2 or SS 1 is selected in |
|
|
|
| CR Emer (FA) |
|
| SL |
| item 1.) or Selects the cycle rate for Emergency | |||
|
|
|
|
|
|
|
|
|
|
|
| mode and Auxiliary stage if Heat Pump is |
|
|
|
|
|
|
|
|
|
|
|
| selected in item 1. |
8 | 7 | 7 | MENU | CL (OFF) |
| CL On |
| Compressor Lockout Time | ||||
9 | 8 | 8 | MENU | Heat Auto | Heat Cool Off, |
| System Mode Configuration | |||||
|
|
|
| Cool Off | Heat Off with Fan icon, | with Automatic Changeover capability | ||||||
|
|
|
|
| Heat Off without Fan icon |
| ||||||
|
|
|
|
| Cool Off, Auto Off |
| ||||||
10 | 9 | 9 | MENU | dL (On) |
| dL OFF |
| Selects Display Light On or OFF | ||||
11 | 10 | 10 | MENU | 0 | 1 HI, 2 HI, 3 HI, 4 HI, | Adjustable Ambient Temperature Display | ||||||
|
|
|
| (current temperature) | 1 LO, 2 LO, 3 LO, 4 LO |
| ||||||
12 | 11 | 11 | MENU | °F |
|
| °C |
| Selects Fahrenheit/Celsius Temperature Display | |||
13 | 12 | 12 | MENU | L Heat | L 62 to L 89 |
| Selects Limited HEAT Range | |||||
|
|
|
| (90) |
|
|
|
|
|
|
|
|
14 | 13 | 13 | MENU | L Cool | L 46 to L 82 |
| Selects Limited COOL Range | |||||
|
|
|
| (45) |
|
|
|
|
|
|
|
|
15 | 14 | 14 | MENU | P7 |
|
| P3 |
| Defaults for 7 day programming (P7) or 5/1/1 | |||
|
|
|
|
|
|
|
|
|
|
|
| day programming (P3) is available |
16 | 15 | 15 | MENU | Heat AS (On) |
|
| OFF |
| Automatic Schedule for heat mode. | |||
17 | 16 | 16 | MENU | Cool AS (On) |
|
| OFF |
| Automatic Schedule for cool mode. | |||
18 | 17 | – | MENU | Heat FA (On) |
|
| OFF |
| Fast Heat option may be disabled by | |||
|
|
|
|
|
|
|
|
|
|
|
| selecting OFF. NA to SS config. |
19 | 18 | – | MENU | Cool FA (On) |
|
| OFF |
| Fast Cool option may be disabled by | |||
|
|
|
|
|
|
|
|
|
|
|
| selecting OFF. NA to SS config. |
|
|
|
|
|
|
|
|
|
|
|
| NA to Heat only system. |
20 | 19 | 17 | MENU | dS (On) |
|
| OFF |
| Selects Automatic daylight Savings Time option | |||
|
|
|
|
|
|
|
|
|
|
|
| On or OFF. |
21 | 20 | 18 | MENU | Change Filter (OFF) |
|
| On |
| Selects Filter | |||
|
|
| MENU | Change Filter (200 h) |
| Change Filter time in 25 hour increments. This | ||||||
|
|
|
|
|
|
|
|
|
|
|
| menu only appears if On is selected in above. |
22 | 21 | 19 | MENU | Cool On (o) | Heat On (b) |
| Selects operation of the reversing valve terminal | |||||
|
|
|
|
|
|
|
|
|
|
|
| (O/B) output as an O or B terminal. |
23 | 22 | 20 | RUN |
|
|
|
|
|
|
|
| Returns to Normal Operation |
|
|
|
|
|
|
|
|
|
|
|
|
|
6