2.Manual Changeover (Heating/Cooling Systems Only)

ON

 

 

 

 

 

Switch #1 OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch #2 OFF

 

 

 

 

 

 

 

Switch #3 (see step B5)

1

2

3

 

 

 

3.Heat Only Systems

ON

 

 

 

 

 

Switch #1 OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch #2 ON

 

 

 

 

 

 

 

Switch #3 (see step B5)

1

2

3

 

 

 

4.Cool Only Systems

ON

 

 

 

 

 

Switch #1 ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch #2 ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch #3 (see step B5)

1

2

3

 

 

 

5.Computed Energy Management Recovery (EMR)

— With EMR enabled, system will be energized before the next program period begins, to achieve programmed temperature by the beginning of the next program period.

ON

 

 

 

 

 

Switch #1 (see steps B1–B4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch #2 (see steps B1–B4)

 

 

 

 

 

 

 

Switch #3 OFF

1

2

3

 

 

 

C. ELECTRIC HEAT SYSTEMS

For central electric heat systems where the blower is energized by a separate circuit through the fan relay (meaning that the fan turns on immediately on call for heat), clip wire W14 on the back of the thermostat (see fig. 13). If the thermostat is energizing electric heat sequenc- ers, DO NOT clip wire W14.

CHECK THERMOSTAT OPERATION

NOTE

When checking thermostat, Group B option switches #1 and #2 for automatic changeover must be in the OFF position. This will allow temporary setting of heat setpoints above cool setpoints. After system checkout, reset Group B option switch #1 to ON position if automatic changeover is desired (see SET GROUP B OPTION SWITCHES).

FAN OPERATION

1.Turn on power to the system. If the heat source has a standing pilot, be sure to light it.

2. Press

FAN

until FAN ON is displayed. The blower

ON – AUTO

should begin to operate (this will work only on sys- tems with a G terminal).

3. Press

FAN

until FAN AUTO is displayed. The

ON – AUTO

blower should stop operating within approximately one minute.

HEATING SYSTEM

1. Press

SYSTEM

until HEAT is displayed (it may already

HEAT-OFF-COOL-AUTO

be displayed).

2.Press to adjust thermostat above room tem- perature to call for heat. The heating system should begin to operate.

COOLING SYSTEM

!CAUTION

To prevent compressor and/or property damage, if power to the compressor has been off or interrupted for more than 1 hour and the outdoor temperature is below 50°F, DO NOT operate the system for at least the amount of time the com- pressor was off! This will allow the compressor heaters to warm the compressor oils to avoid damage due to slugging.

1. Press

SYSTEM

until COOL is displayed.

HEAT-OFF-COOL-AUTO

2.Press to adjust thermostat below room tem- perature to call for cool. The blower should come on immediately, followed by cold air circulation. How- ever, if the red LED on the thermostat front is flashing, the compressor lockout feature is operating (see Lockout Bypass Option to temporarily override the compressor lockout feature during testing).

After the system has been checked and is running prop- erly, determine if automatic changeover is desired (see

SYSTEM CONFIGURATION).

LOCKOUT BYPASS OPTION

FOR QUALIFIED SERVICE TECHNICIANS’ USE ONLY. OPERATORS SHOULD NOT USE THIS FEATURE DUE TO POSSIBILITY OF EQUIPMENT OR PROPERTY DAMAGE, OR PERSONAL INJURY.

COMPRESSOR SHORT TERM

CYCLE PROTECTION

This thermostat has a built-in short term (5-minute) time delay. During this 5-minute period, the thermo- stat will lock out the compressor to allow head pres- sure to stabilize. If you want to override this feature

while testing thermostat operation, simply press TEMPVIEW and PRGMVIEW buttons at the same time at initial startup.

DO NOT USE THE LOCKOUT BYPASS OPTION UNLESS THE COMPRESSOR OIL HEATERS HAVE BEEN OPERATIONAL FOR 6 HOURS AND THE SYSTEM HAS NOT BEEN OPERATIONAL FOR AT LEAST 5 MINUTES.

7

Page 7
Image 7
White Rodgers 1F97W-71 Check Thermostat Operation, Electric Heat Systems, FAN Operation, Heating System, Cooling System

1F97W-71 specifications

The White Rodgers 1F97W-71 is a highly versatile and advanced digital thermostat designed to enhance heating and cooling systems in residential environments. This unit stands out for its blend of modern technology, user-friendly features, and energy efficiency, making it a popular choice among homeowners looking to optimize their indoor climate control.

One of the main features of the 1F97W-71 is its large, easy-to-read touchscreen display. The intuitive interface allows users to effortlessly navigate through settings, making adjustments to temperature and scheduling straightforward. The thermostat provides precise temperature control, ensuring that your home stays comfortable while reducing energy consumption.

This model is equipped with a 7-day programmable schedule, giving users complete control over their heating and cooling patterns. Homeowners can set different temperature settings for each day of the week, allowing for personalized comfort based on their schedules. This feature not only enhances comfort but also contributes to energy savings, as it can automatically reduce heating or cooling when the home is unoccupied.

The 1F97W-71 also incorporates advanced technologies, such as Smart Recovery, which learns how long it takes to reach your desired temperature and starts the heating or cooling process in advance to ensure that your home is at the right temperature at the scheduled times. The thermostat is compatible with various heating and cooling systems, including multi-stage systems, heat pumps, and conventional HVAC setups.

Another notable characteristic of the White Rodgers 1F97W-71 is its Wi-Fi capability. This allows users to remotely access and control their thermostat via a smartphone app, offering the convenience of making adjustments on-the-go. With the app, users can monitor energy usage, receive alerts, and even access weather forecasts to make informed decisions about their home climate.

Energy efficiency is a cornerstone of the 1F97W-71's design. It has ENERGY STAR certification, indicating that it meets strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This certification not only helps contribute to a more sustainable environment but can also lead to significant savings on energy bills over time.

In conclusion, the White Rodgers 1F97W-71 is a feature-rich digital thermostat that combines user-friendly controls, advanced technology, and energy efficiency to provide an optimal home climate solution. Its programmable scheduling, Wi-Fi connectivity, and compatibility with various HVAC systems make it a standout choice for homeowners seeking to enhance their comfort while managing energy costs.