White Rodgers 2274W installation instructions 2271/72/73/74W, Installation Instructions, Contents

Models: 2271W 2274W 2273W 2271 2272W

1 10
Download 10 pages 52.06 Kb
Page 1
Image 1
2271/72/73/74W

2271/72/73/74W

Line or Low Voltage

Humidistat / Dehumidistat

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

These wall-mounted, line or low voltage humidity controls are available as a Humidistat commonly used to control and operate a furnace humidifier or as a Dehumidistat commonly used to cycle an air conditioning system to control humidity in an unoccupied home to prevent mil- dew build-up associated with high humidity levels.

These humidity controls feature a moisture-sensitive nylon sensing element and also provide positive ON-OFF settings for manual operation.

2271W

2274W

PRECAUTIONS

If in doubt about whether your wiring is line, or low voltage, have it inspected by a qualified heating and air condition- ing contractor, electrician, or someone familiar with basic electricity and wiring.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

CONTENTS

 

Description

1

Precautions

1

Specifications

2

Installation

2

Select Humidity Control Location

 

Route Wires to Location

 

Wiring

 

Attach Humidity Control to Wall

 

Operation

4

Humidistat Control

 

Dehumidistat Control

 

Line or Low VoltageCAUTION

To prevent electrical shock and/or equipment dam- age, disconnect electric power to system, at main fuse or circuit breaker box, until installation is complete.

Do not short out terminals on primary control to test. Short or incorrect wiring will burn out humid- ity control and could cause personal injury and/or property damage.

INSTALLATION INSTRUCTIONSWARNING

Do not use on circuits exceeding the rated volt- age. Higher voltage will damage control and could cause shock or fire hazard.

White-Rodgers is a division

PART NO. 37-9600D

of Emerson Electric Co.

Replaces 37-9600C

www.white-rodgers.com

0528