White Rodgers 37-5086A, 37-5086B installation instructions Mv Rh

Models: 37-5086A 37-5086B

1 8
Download 8 pages 44.33 Kb
Page 5
Image 5
MV

6MV

Millivolt

System

 

 

 

 

 

THERMOSTAT

Y

G

W

RC

RH

6

 

 

 

 

 

SYSTEM

MV

RH

Figure 8. Typical wiring diagram for millivolt systems

From millivolt system

 

W

W

 

 

MV

 

RC

 

 

G

 

 

Y

From millivolt system

Thermostat Terminal Connections

6MV

Millivolt

System

Y

Cooling

System

G

Fan

Relay

W

RC

RH

THERMOSTAT

SYSTEM

 

 

 

 

 

 

Hot

 

 

24 VAC

120 VAC

 

 

 

Neutral

 

 

TRANSFORMER

6

MV

RH

From millivolt system

From 24 VAC

transformer

 

W

W

 

 

MV

RC

RC

 

 

 

G

G

 

Y

Y

From fan relay

From cooling system

Thermostat Terminal Connections

Figure 9. Typical wiring diagram for millivolt systems + cool only, 3-wire systems

From zone valve

6

64

Zone 5

Valve

12

MV

Y

G

W

RC

RH

THERMOSTAT

6

 

W

W

SYSTEM

6

 

 

 

 

 

 

 

MV

 

 

RC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

Hot

 

RH

 

Y

 

 

 

 

 

24 VAC

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RH

 

 

 

 

 

 

 

 

 

Neutral

From 24 VAC transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(through zone valve)

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat Terminal Connections

Figure 10. Typical wiring diagram for heat only, 3-wire, zone valve systems

6

MVY

Cooling

System

G

Fan

Relay

W

Heating

System

RC RH

THERMOSTAT

 

SYSTEM

 

 

24 VAC

 

 

 

 

 

 

Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

HEATING TRANSFORMER

24 VAC

 

 

 

 

 

 

Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

COOLING TRANSFORMER

 

From heating

From 24 VAC

system

 

cooling transformer

 

6

W

W

MV

RC

RC

G

 

G

 

Y

 

Y

 

RH

RH

From fan relay

 

 

 

 

From 24 VAC

From cooling

 

system

heating transformer

 

Thermostat Terminal Connections

Figure 11. Typical wiring diagram for heat/cool, 5-wire, two-transformer system

4.Place subbase over hole in wall and mark mounting hole locations on wall using subbase as a template.

5.Move subbase out of the way. Drill mounting holes.

6.Fasten subbase loosely to wall, as shown in fig. 3, using two mounting screws. Place a level against bottom of subbase, adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing

mounting holes, or if holes drilled are too large and do not allow you to tighten subbase snugly, use plastic screw anchors to secure subbase.

7.Push excess wire into wall and plug hole with a fire- resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

5

Page 5
Image 5
White Rodgers 37-5086A, 37-5086B installation instructions Mv Rh