White Rodgers F92-0737 installation instructions Natural to Unregulated L.P. Gas Conversion Kit

Models: F92-0737

1 2
Download 2 pages 43.43 Kb
Page 1
Image 1
F92-0737

F92-0737

Natural to Unregulated L.P. Gas

Conversion Kit

INSTALLATION INSTRUCTIONSInstaller: Save these instructions for future use!

FAILURETO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

!WARNING

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, ex- plosion, or production of carbon monoxide may result, causing property damage, personal injury, or loss of life. The qualified service agency performing the work assumes the responsibility for the proper conversion of this appliance with this kit.

Regulator

Cover ScrewNatural to Unregulated L.P. Gas

Blocking Pin

 

Spring

Plastic Regulator

 

 

Adjustment Screw

APPLICATION

This regulated Natural Gas to unregulated L.P. Gas conversion kit allows the 36C, 36E and 36J Series gas valves to be used on L.P. gas applications, PROVIDED an external regulator is used and the inlet pressure does not exceed 14”W.C. This conversion kit is for use on all single stage, fast and slow open models only.

TO CONVERT FROM NATURAL TO L.P. GAS

1.Remove regulator cover screw.

2.Insert the spring (provided in the conversion kit) through the hole in the center of the plastic regulator adjustment screw.

3.Insert the blocking pin (provided in the conversion kit) down into the center of the spring.

4.Replace the regulator cover screw.

5.Attach theWARNING label (provided in the kit) to the gas valve where it can be readily seen. Also attach the small round L.P. label to the top of the regulator cover screw.

6.If present pilot burner is to be used, the pilot orifice must be replaced.

Conversion back to Natural Gas use may be made at a later date by removing the spring and blocking pin (installed in steps 2 and 3, above) and removing the WARNING and L.P. labels.

Figure 1. 36C model

 

Regulator Cover

Regulator

Screw

 

Cover Screw

Blocking Pin

 

Blocking Pin

Spring

Spring

Plastic Regulator

Plastic Regulator

Adjustment Screw

Adjustment Screw

 

Figure 3. 36J model

Figure 2. 36E model

! WARNING

VALVE CONVERTED FOR USE ON L.P.

GAS. REGULATOR BLOCKED OPEN.

EXTERNAL REGULATOR REQUIRED.

IMPROPER OPERATION COULD RESULT

IN DEATH OR SERIOUS INJURY.

! MISE EN GARDE

SOUPAPE CONVERTIE POUR USAGE

SUR GAZ DE PÉTROLE LIQUÉFIÉ.

RÉGULATEUR BLOQUÉ EN POSITION

OUVERTE. RÉGULATEUR EXTERNE

NÉCESSAIRÉ. UN FONCTIONNEMENT

INAPPROPRIÉ PEUT PROVOQUER LA

MORT OU DES BLESSURES GRAVES.

WARNING Label

Spring LP

Blocking

L.P. Label

Pin

 

Figure 4. Contents of kit

White-Rodgers is a division

www.white-rodgers.com

PART NO. 37-5382E

Replaces 37-5382D

of Emerson Electric Co.

 

 

0943

 

 