F92-1011

Regulated L.P. to Natural Gas

Conversion Kit for 36G/36J Two-Stage

INSTALLATION INSTRUCTIONS

Installer: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

!WARNING

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explo- sion, or production of carbon monoxide may result, causing property damage, personal injury, or loss of life. The qualified service agency performing the work assumes the responsibility for the proper conversion of this appliance with this kit.

APPLICATION

This conversion kit allows the 36G Series and 36J Series Two- Stage gas valves to be used on Natural gas applications. This conversion kit is for use on all 36G/36J Two-Stage, fast and slow open models.

High Low

Regulator

Cover Screw

Plastic Regulator

Adjustment Screw

Regulator Spring

Figure 1. 36G/36J 2-Stage models

TO CONVERT FROM L.P. TO NATURAL GAS

1.Remove both regulator cover screws.

2.Remove both regulator adjustment screws (beneath the cover screws).

3.Remove both regulator springs from regulator sleeves. (L.P. configuration may be two L.P. springs, color-coded white, or one L.P., color-coded white, and one Natural, color-coded silver/plain).

4.Insert the Natural Gas regulator springs (provided in the conversion kit and color-coded silver/plain) into the regulator sleeves.

5.Replace the High regulator adjustment screw and adjust approximately 14 turns from top of sleeve.

6.Replace the Low regulator adjustment screw and adjust approximately 10 turns from top of sleeve.

7.Adjust both outlet pressures to the appliance manufacturer's requirements.

8.Replace both regulator cover screws.

9. Remove the L.P. WARNING label, if

 

! WARNING

present, from the gas valve. Also attach the

VALVE CONVERTED FOR USE ON L.P.

RESULT IN DEATH OR SERIOUS

 

GAS. IMPROPER OPERATION COULD

small round NAT GAS labels to the top of

INJURY.

! MISE EN GARDE

the regulator cover screws.

SOUPAPE CONVERTIE POUR USAGE

UN FONCTIONNEMENT INAPPROPRIÉ

 

SUR GAZ DE PÉTROLE LIQUÉFIÉ.

 

PEUT PROVOQUER LA MORT OU DES

 

BLESSURES GRAVES.

 

WARNING Label

Natural Gas Regulator

Springs (silver/plain)

NAT. NAT.

GAS GAS

Natural Gas Labels

Figure 2. Contents of kit

White-Rodgers is a division

PART NO. 37-6586B

of Emerson Electric Co.

Replaces 37-6586A

www.white-rodgers.com

1005

Page 1
Image 1
White Rodgers F92-1011 installation instructions Installation Instructions, Application

F92-1011 specifications

The White Rodgers F92-1011 is a versatile and highly efficient programmable thermostat designed to enhance home comfort and energy savings. This model is part of the industry’s push towards more intelligent temperature control systems, integrating advanced technologies and user-friendly features.

One of the primary features of the F92-1011 is its programmable capability, allowing users to set different temperature levels for various times of the day and days of the week. This flexibility ensures that heating and cooling systems operate only when needed, leading to significant energy savings. The thermostat provides four programming periods per day, allowing for detailed customization according to lifestyle needs. Whether the user is at home, away, or sleeping, this capability ensures optimal comfort while minimizing energy consumption.

In terms of technology, the F92-1011 boasts a large, easy-to-read digital display that simplifies temperature adjustments and programming. The intuitive interface is user-friendly, making it accessible for individuals of all tech-savviness levels. It also features a backlit option, making it easy to read in low-light conditions.

Another notable characteristic of the F92-1011 is its compatibility with various heating and cooling systems. It can be used with gas, electric, and heat pump systems, making it a versatile choice for many households. Additionally, the thermostat utilizes advanced algorithms to ensure precise temperature control, maintaining desired settings within a narrow tolerance range.

The F92-1011 is also equipped with a filter change indicator, alerting users when it's time to replace or clean their HVAC system filters. This feature is essential for maintaining air quality and efficiency in heating and cooling systems, further contributing to energy savings and performance longevity.

Moreover, installation is straightforward, as the unit is designed for DIY enthusiasts while also allowing for professional installation. With its robust performance and reliable features, the White Rodgers F92-1011 stands out as a solid investment for homeowners looking to enhance their control over indoor climates.

In summary, the White Rodgers F92-1011 showcases a blend of practicality, efficiency, and technology. Its programmable settings, compatibility with multiple systems, user-friendly interface, and energy-saving features make it an ideal choice for modern home temperature management.