OZONE REDUCTION
All electronic air cleaners typically produce a small amount of ozone that is within established limits. Some customers may notice an odor especially at high altitudes or low air flow rates.
This power supply has a “hairpin” shaped jumper wire labeled W1 that can be cut and separated in case of such complaints. This will cause the power supply to limit the maximum operating power to a lower level.
SSC1000
WIRING DIAGRAM
W1
Cut and separate
Ozone Reduction
Jumper
WHT/BRN |
| BLK | |||||
|
|
|
|
|
|
|
|
E3 | LINE | E2 | |||||
|
|
|
|
|
|
|
6