WHITE-RODGERS

TYPE 151

ROOM THERMOSTAT

Cooling Service, External Dial

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

These room thermostats have been designed for control- ling cooling equipment operating on line voltage with heavy electrical loads. They are suitable for operation of unit coolers, room coolers, etc., or any similar refrigera- tion application requiring a heavy duty room thermostat.

Models are available with various ranges for meeting the needs of almost any application.

W

H

I T E-R O DGERS

90

7080

5060

40

THESE CONTROLS MUST BE INSTALLED BY A QUALIFIED INSTALLER.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

This control has been accurately calibrated at the factory. Any attempt to calibrate this control will void the White- Rodgers warranty.

PRECAUTIONS

CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system, at main fuse or circuit breaker box, until installation is complete.

WARNING

Do not use on circuits exceeding specified volt- ages. Higher voltages will damage control and could cause shock or fire hazard.

The proper location of a heavy duty room thermostat is very important to assure good performance. The following general rules will help in determining the proper location:

1.Make sure that it is in a place where air circulates around it freely. This is important.

2.Never install it on or near an outside wall.

3.Keep it away from windows or doors.

4.Don’t locate it too close to a strong light or any other false source of heat such as direct sunlight, steam lines, etc.

5.Mount it on a post or a partitioning wall, but make sure that there are no pipes or duct work in that wall or directly behind it.

6.If the electrical conduit leads into a cooler or a warmer room, plug up the space around the wires in the conduit with rock wool.

INSTALLATION

CONCRETE

PLASTER

JUNCTION BOX

THERMOSTAT

CONDUIT

INSIDE WALL

CONDUIT

ALONG WALL

WALL INSTALLATION

The mounting plate for this thermostat has two holes 35/16”apart for attaching the control on a standard switch box.

Figure 1

WHITE-RODGERS DIVISION

 

EMERSON ELECTRIC CO.

 

9797 REAVIS RD., ST. LOUIS, MO. 63123

 

(314) 577-1300, FAX (314) 577-1517

Printed in U.S.A.

 

9999 HWY. 48, MARKHAM, ONT. L3P 3J3

 

(905) 475-4653, FAX (905) 475-4625

 

PART NO. 37-1118B

Replaces 37-1118 9548

Page 1
Image 1
White Rodgers TYPE 151 installation instructions Room Thermostat, Description, Precautions, Installation

TYPE 151 specifications

The White Rodgers TYPE 151 is a premier thermostat designed for optimal heating and cooling control in residential and commercial settings. Renowned for its precision and reliability, the TYPE 151 offers users a blend of sophisticated technology and user-friendly simplicity, making it a popular choice among HVAC systems.

One of the main features of the White Rodgers TYPE 151 is its compatibility with various heating and cooling systems, including gas, oil, electric, and heat pump configurations. This versatility allows homeowners and businesses alike to utilize the thermostat across a wide range of applications. The device is particularly lauded for its ability to manage multi-stage heating and cooling, accommodating more complex systems which require coordinated control for efficient operation.

Technologically, the TYPE 151 is equipped with an electronic control system that enhances its accuracy and responsiveness. This enables the thermostat to maintain the desired indoor temperature more effectively compared to traditional mechanical models. The advanced electronic circuitry can quickly assess temperature variations and adjusts the heating or cooling output accordingly, providing a more stable and comfortable environment. Moreover, its temperature range typically spans from 40°F to 100°F, allowing for broad usage in different climates.

Another key characteristic of the TYPE 151 is its intuitive interface, which often includes a clear display and straightforward buttons. This design minimizes the learning curve for users, making temperature adjustments simple and hassle-free. Additionally, many models are equipped with a battery backup, ensuring that the thermostat continues to function even during power outages, a crucial feature for maintaining climate control in critical situations.

Users also appreciate the reliability and long lifespan of White Rodgers products, which are built with high-quality components designed to withstand the rigors of daily use. In addition, the TYPE 151 often supports advanced programming options, allowing for customized schedules that help optimize energy use and reduce utility costs.

In summary, the White Rodgers TYPE 151 thermostat stands out in the HVAC market due to its versatility, technological advancements, ease of use, and durability. It equips users with the tools necessary to achieve an efficient and comfortable climate in their living or working spaces, making it a valuable addition to modern climate control solutions.