Compact Heating System
Model Number | Btu/hr Input | Btu/hr Output | Efficiency Percentages | Type | Gas | Shipping Weight | |||
|
|
|
| of | |||||
Natural | Propane | Rating | Rating | Thermal | AFUE | Connection | (lbs.) | ||
Control | |||||||||
|
|
|
|
|
|
|
| ||
2503532 | 2503531 | 25,000 | 19,250 | 77.0 | 76.0 | 24V Wall | ⅜" | 65 | |
4003532 | 4003531 | 40,000 | 30,800 | 77.0 | 76.0 | 24V Wall | ⅜" | 98 |
Features
Unique, Self-Contained Direct-Vent System
With either wall or window installation, the Compact Heating System requires no chimney or flue pipe. The sealed combustion system uses only outside air, and the exhaust gases are discharged directly to the outside.
There's a Model for
Your Space Heating Needs
Furnace dimensions and easy installation allow for placement and operation through most windows and exterior walls. Consult this drawing and chart below for sizes.
Easy Installation
Through-the-Wall or Through-the-Window
The Compact Heating System offers exceptional installation flexibility found in no other
Williams compact design incorporates an attractive front grille that extends only 3¼ inches into the room, saving valuable interior space.
The 250 Series Models fit between standard 16" O.C. studs with no structural changes needed.
Model | A | B | C | D | E | F |
250 Series | 16⅛" | 23⅝" | ||||
400 Series | 21¾" | 23⅝" |
How to Select the Right Model
Use the chart shown to determine the appropriate model to provide proper heating capacity for your square footage.
|
| Amount of Insulation | ||
Model | Well Insulated | Average | Poor | |
| Insulation | Insulation | ||
|
|
| ||
250 Series | 1,225 sq. ft. |
| 825 sq. ft. | 625 sq. ft. |
|
|
|
|
|
400 Series | 2,050 sq. ft. |
| 1,350 sq. ft. | 1,000 sq. ft. |
|
|
|
|
|
Dimensions and Clearances
Cabinet Clearances
All models, top, bottom and sides 0", rear 36".
Grille Clearances
All models, top to ceiling 12", adjacent side wall 12", front 8', floor 6" (2" if noncombustible).
Wall Opening Size
25,000 Btu/hr models: 14¼"W x 13⅝"H 40,000 Btu/hr models:
250 West Laurel Street · Colton, California 92324 USA
(909)
Homeowner Assistance: (909)
Important
·Read owner's manual before using/installing.
·Photographs are representative.
·Check local codes and ordinances for permitted uses.
·Consult installation manual for clearances prior to installation.
·We reserve the right to amend product specifications without notice.
·Installation and servicing recommended by a qualified service person.
·New York approval
·Minneapolis certificate of approval number 5787.
·Please read the warranty for any limitations for disclaimers.
·Combustion chamber carries a
© 2008 Williams Furnace Co. | Printed in U.S.A. | All Rights Reserved | Subject to Change without Notice | L1136 | 5/08 |