Williams 6005622 Floor Furnace, Easy Installation, Features, Accessories, Requires No Electricity

Models: 6005622 4505622 6005621 4505621

1 2
Download 2 pages 43.4 Kb
Page 2
Image 2
Floor Furnace

Floor Furnace

Model NumberBtu/hr

Btu/hr

Efficiency Percentages

 

Dimensions

 

Floor OpeningShipping

 

 

 

 

 

 

 

 

 

 

 

NaturalPropaneInputOutput

Thermal

AFUE

Width

 

Length

 

Height

Width

Length

Weight (lbs.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4505622

4505621

45,000

31,500

70.0

57.0

24"

 

32"

 

28½"

24¼"

32⅜"

147

6005622

6005621

60,000

42,000

70.0

58.0

24"

 

42"

 

28½"

24¼"

42⅜"

174

All units have ½" gas connection.

Easy Installation

NOTE: If two joists are cut, use a double header

Headers

Floor

Model NumberFloor

Joist

This space must be the same size as the opening cut in the floor

NOTE: The headers must not be a smaller size lumber than the joists

Btu/hrFurnace

Features

Floor Register Temperature Control

Williams' floor furnaces are equipped with automatic floor register grille temperature control. This meets the latest American National Standards Institute Requirements. In extreme weather conditions, this control can be overridden to allow increased heat output.

Temperature Control

A self-generating millivolt electrical system powers a wall- mounted heating thermostat. This provides maximum room comfort while allowing economical automatic operation.

Accessories

High-Altitude Units

Conversion Kits

VENTILATION OPENING

FIRST FLOOR

4" VENT PIPE

(¼" RISE PER FOOT)

12"

GROUND LEVEL

DRAIN FROM

FURNACE PIT

12" MINIMUM

12" MINIMUM ON ALL SIDES EXCEPT CONTROL END OF FURNACE

JOIST HEADERS

 

 

 

 

 

 

DEPTH OF

 

FURNACE

18" MINIMUM

 

 

WORK SPACE

 

 

 

18" MINIMUM ON CONTROL END OF FURNACE

Requires

No Electricity

Great During

Power Outages

All units have 4" flue pipe diameter and 18" floor-to-center of flue connection.

Recommended Minimum Clearances

6" between the floor furnace and adjacent walls

12" between the floor furnace and doors, draperies or other combustible materials

15" walk space along two sides of the furnace

250 West Laurel Street · Colton, California 92324 USA

(909)825-0993 · Fax: (909) 370-0581 or (909) 824-8009 Consumer Line: (888) 256-6465

Homeowner Assistance: (909) 426-0978 www.e-wfc.com

Important

·Read owner's manual before using/installing.

·Photographs are representative only.

·Specify propane or natural gas when ordering.

·Check local codes and ordinances for permitted uses.

·Consult installation manual for clearances prior to installation.

·We reserve the right to amend product specifications without notice.

·Installation and servicing recommended by a qualified service person.

·Please read the warranty, for any limitations or disclaimers. Combustion chamber carries a ten-year limited warranty. All other parts carry a one-year

li.llimited warranty.

·Venting must comply with the "Venting and Chimney Requirements" section of the

...installation manual.

·Replacement floor furnaces of the same or lesser Btu/hr input rating may be installed in the same location as the replaced furnace when replacement does not create an unsafe condition.

© 2008 Williams Furnace Co.

Printed in U.S.A.

All Rights Reserved

Subject to Change without Notice

L1026 5/08