Forsaire Electric Furnace
|
| Heating Output Btu/hr | Operating |
| Dimensions |
| CFM |
| Discharge Air | Shipping Weight | |||
Model | KW Input |
|
|
|
|
|
|
| AMPS | ||||
|
| Voltage |
|
|
|
|
| 115V | Temp at 240V | (lbs.) | |||
at 240V | at 208V | Width |
| Depth |
| Height | |||||||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3144030 | 9.2 | 31,400 | 23,600 | 207 - 253 | 14⅛" |
| 7" |
| 72½" | 375 | 40 | 80oF Rise | 60 |
Easy Installation
Forced air electric wall furnace requires less than one square foot of floor space and provides warm air circulation for maximum comfort.
The 9.2 kW input, 31,400 Btu/hr output model delivers heat into one or two rooms by a large, quiet blower. This model may be recessed into the stud space or surface mounted. With a cabinet depth of seven inches, recessed installation provides a projection of only three inches into the living space. A freestanding application solves the problem in otherwise
Dimensional Data
TOP6½"
2¼"
7"
14⅛"
18⅜"
| S | 72½" | BACK |
|
| ||
|
|
| |
FRONT | I |
|
|
D |
|
| |
|
|
| |
| E |
|
|
|
|
| 12" |
|
|
| 8" |
Finished |
|
| 4⅞" |
Floor |
|
| |
|
|
|
Features
All wiring and controls are easily accessible from the front. Transformer, terminal block, relay and motor are factory- prewired with thermostat wires pigtailed outside. Total system plus individual elements are protected by safety limit switches.
Blower System
Powerful,
Thermostat
Relay and
Accessories |
|
|
|
Mount flush on rear wall for heat to be delivered through the |
|
register. |
|
Model 6501, shipping weight 7 lbs. | 6501 |
Diffuser Grille |
|
| |
A |
|
air discharges from the front, a diffusing grille can be used to |
|
divert heat to the right, left or both directions. |
|
Model 6704 - | 6704 |
| |
Shipping weight 3 lbs. |
|
| |
Model 6703 - |
|
Shipping weight 3 lbs. |
|
6703
Typical Installations
RECESSED | RECESSED | FREESTANDING | FREESTANDING |
WITH OPTIONAL | WITH FRONT | WITH OPTIONAL | WITH FRONT |
REAR OUTLET | OUTLET ONLY | REAR OUTLET | OUTLET ONLY |
250 West Laurel Street · Colton, California 92324 USA
(909)
Homeowner Assistance: (909)
Recommended Minimum Clearances
6" between the furnace and adjacent walls
0" between the furnace and floor
Important
·Read owner's manual before using/installing.
·Photographs are representative only.
·Check local codes and ordinances for permitted uses.
·Consult installation manual for clearances prior to installation.
·We reserve the right to amend product specifications without notice.
·Installation and servicing recommended by a qualified service person.
·Please read the warranty for any limitations or disclaimers. All parts carry a
© 2008 Williams Furnace Co. | Printed in U.S.A. | All Rights Reserved | Subject to Change without Notice | L1005 05/08 |