4. Close the blade cover and secure with four knobs.

 

source, or that the fuses have been removed or

Electrical

 

breakers tripped in the circuit in which the saw will

 

be connected. Make sure you put a warning plac-

Observe the following when connecting to the power

 

ard on the fuse or circuit breaker to prevent acci-

source. (The cut-off saw wiring diagrams are pro-

 

dental electrical shock.

vided in Figures 21 and 22.)

2.

If you are installing the motor power cord into a

WARNING: WILTON RECOMMENDS THATANY WIR-

 

receptacle, make sure to use the appropriate plug.

3.

If you are using hard-wired connections to a junc-

ING INVOLVING HARD WIRING OF THE SAW TO A

 

tion box, connect the wires in the box, and close

BRANCH, ORANY CHANGE OF VOLTAGE SUPPLIED

 

 

the box.

TO THE MOTOR BE PERFORMED BY A LICENSED

 

4.

Install the fuses or reset the breaker.

ELECTRICIAN.

1. Make sure the saw is disconnected from the power

5.

The saw is now ready for service.

 

 

18

Figure 21: Model 7020 cut-off saw wiring diagram

115V - To reverse motor rotation switch terminals 5 and 6.

220V - To reverse motor rotation hook terminal 6 to 1.

Figure 22: Connection diagram for 1ph motor

Page 17
Image 17
Wilton 7020/7040 manual Electrical, Model 7020 cut-off saw wiring diagram