Wind Crest installation instructions Hoods without Heat Lamps, CFM = VEN100E, CFM Rating

Models: VEN100E

1 2
Download 2 pages 43.99 Kb
Page 1
Image 1
Externally Mounted Ventilators – Install Quick Specs

Externally Mounted Ventilators – Install Quick Specs

VEN100E

Installation Type & Discharge Direction Mounted outside. Can be mounted on exterior roof or wall.

CFM Rating

1000 CFM = VEN100E

Minimum Duct Size 10” round

Maximum Equivalent Straight Duct Length

50 feet

Equivalent Straight Lengths

1 foot of 8” or 10” duct = 1 foot

1 foot of 3 ¼” x 14” rectangular = 1 foot

8” round 90 degree Elbow = 5 feet

10” round 90 degree Elbow = 3 feet

Wall or Roof Cap = 2 feet

Ventilator Carton Weight:

VEN100E = 80 lbs.

7"

4"

 

 

"

24

0

3

 

"

 

 

 

VEN100E
Standard Features

Adaptable to all Wind Crest hoods

Weather-resistant galvanized steel construction

Thermally protected, permanently lubricated motor

Dynamically balanced 11” diameter blower wheel

Neoprene resilient anti-vibration mounted

Built-in Flashing plate for roof or wall mount

Easily removed blower cover for periodic cleaning

UL LISTED 7Z66

C UL

Ventilator Motor Ratings*

Hoods without Heat Lamps:

8.0Amps @ 120 V AC, 60 Hz Hoods with Heat Lamps:

12.4Amps @ 120 V AC, 60 Hz

*For maximum power supply required, refer to hood series selected.

Copyright 2006 Wind Crest by CNP Industries

1

Install Quick Specs are for planning purposes only. Please refer to the detailed installation instructions, prior to making any cutouts.

Page 1
Image 1
Wind Crest installation instructions Externally Mounted Ventilators - Install Quick Specs VEN100E, CFM = VEN100E