Externally Mounted Ventilators – Install Quick Specs
VEN150E
Installation Type & Discharge Direction Mounted outside. Can be mounted on exterior roof or wall.
CFM Rating
1500 CFM
Minimum Duct Size
10” round
Maximum Equivalent Straight Duct Length 50 feet
Equivalent Straight Lengths
•1 foot of 8” or 10” duct = 1 foot
•1 foot of 3 ¼” x 14” rectangular = 1 foot
•8” round 90 degree Elbow = 5 feet
•10” round 90 degree Elbow = 3 feet
•Wall or Roof Cap = 2 feet
Standard Features
•Adaptable to all Wind Crest hoods
•
•Thermally protected, permanently lubricated motor
•Dynamically balanced 12” diameter blower wheel
•Neoprene resilient
•
•Easily removed blower cover for periodic cleaning
Ventilator Carton Weight:
VEN150E = 80 lbs.
7"
4"
|
| " |
24 | 0 | |
3 |
| |
" |
| |
|
|
VEN150E
UL LISTED 7Z66 | C UL |
Ventilator Motor Ratings*
Hoods without Heat Lamps:
12.0Amps @ 120 V AC, 60 Hz Hoods with Heat Lamps:
16.4Amps @ 120 V AC, 60 Hz
*20 Amps @ 120 V AC, 60 Hz required when using VEN150E ventilator.
Copyright 2006 Wind Crest by CNP Industries | 1 |
Install Quick Specs are for planning purposes only. Please refer to the detailed installation instructions, prior to making any cutouts.