Externally Mounted Ventilators – Install Quick Specs

VEN150E

Installation Type & Discharge Direction Mounted outside. Can be mounted on exterior roof or wall.

CFM Rating

1500 CFM

Minimum Duct Size

10” round

Maximum Equivalent Straight Duct Length 50 feet

Equivalent Straight Lengths

1 foot of 8” or 10” duct = 1 foot

1 foot of 3 ¼” x 14” rectangular = 1 foot

8” round 90 degree Elbow = 5 feet

10” round 90 degree Elbow = 3 feet

Wall or Roof Cap = 2 feet

Standard Features

Adaptable to all Wind Crest hoods

Weather-resistant glavanized steel construction

Thermally protected, permanently lubricated motor

Dynamically balanced 12” diameter blower wheel

Neoprene resilient anti-vibration mounted

Built-in Flashing plate for roof or wall mount

Easily removed blower cover for periodic cleaning

Ventilator Carton Weight:

VEN150E = 80 lbs.

7"

4"

 

 

"

24

0

3

 

"

 

 

 

VEN150E

UL LISTED 7Z66

C UL

Ventilator Motor Ratings*

Hoods without Heat Lamps:

12.0Amps @ 120 V AC, 60 Hz Hoods with Heat Lamps:

16.4Amps @ 120 V AC, 60 Hz

*20 Amps @ 120 V AC, 60 Hz required when using VEN150E ventilator.

Copyright 2006 Wind Crest by CNP Industries

1

Install Quick Specs are for planning purposes only. Please refer to the detailed installation instructions, prior to making any cutouts.

Page 1
Image 1
Wind Crest VEN150E installation instructions 1500 CFM