Windster RA.3130/3136, RA.3030/3036 operation manual G. Providing Electrical Power, Safety Warning

Models: RA.3030/3036 RA.3130/3136

1 18
Download 18 pages 59.96 Kb
Page 8
Image 8
G. Providing Electrical Power

4.Screw the four 1"wood screws (tor mounting the hood) into the exact center of the arrow and of the keyhole mounting slots marked on the cabinet bottom (for flush installations), or marked on the 1"x2" wood strips (tor recessed cabinet installation) (Fig.7)

Do not turn the mounting screws in all the way. Allow3/8" of screw to project. so the hood can be fitted place. (The screws will be tightened later)

!!

-

~

I

 

D

D

~'

 

Fig.?

G. Providing Electrical Power

Note: Please also refer P.11 "J. Making the Electrical Connection'

1.After turning off the proper 120 volt circuit at the service entrance. drill out the electrical power line access hole marked on the cabinet bottom or wall. Use a 1 v.. "wood bit. To operate the electric drill. use an extension cord connected to another circuit. (Fig.8)

Safety Warning:

Ifdrillinginto the walls. be careful not to cut existing electrical cabbies. whichwouldcreate. a hazard.

2.Fish the electrical power line through the access hole drilled in the wall or bottom of the cabinet. Attach an appropriate connector (purchased locally) to the end of the power line for the type of wiring being installed. Follow all codes.(Fig.9)

Color:

green/white/black

Flg,9