MODEL: IRG
INSTANT RECOVERY GRIDDLE
INSTALLATION REQUIREMENTS:
1.A gas pressure regulator sized for this unit is included. Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2.Gas line connecting to appliance must be ¾" diameter or larger. If flexible connectors are used, the inside diameter must be the same as the ¾" iron pipe.
3.115 volt, 50/60 Hz, 1 phase control circuit. ½ amp draw. Provided with 6' power cord with 3 prong plug.
4.An adequate ventilation system is required for commer- cial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org. When writing, refer to NFPA No. 96.
See equipment stand spec sheets for dimensions.
5.These units are manufactured for installation in accordance with National Fuel Gas Code,
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.
6. Clearances: |
| |
| Combustible | |
Rear | 6" | 0" |
Sides | 6" | 0" |
|
|
|
| Griddle |
|
| Approx. Ship Wt. (lbs./kg) | |
Model |
| Griddle |
| Surface | Overall | No. of | ||
|
|
|
| |||||
No. | BTU/hr. | Width |
| Depth | Width | Controls | Counter | Floor |
|
|
|
|
|
|
|
|
|
IRG36 | 60,000 | 36" | x | 24" | 36" | 3 | 475/214 | 545/245 |
|
|
|
|
|
|
|
|
|
IRG48 | 80,000 | 48" | x | 24" | 48" | 4 | 575/259 | 665/299 |
|
|
|
|
|
|
|
|
|
IRG60 | 100,000 | 60" | x | 24" | 60" | 5 | 666/300 | 855/385 |
|
|
|
|
|
|
|
|
|
IRG72 | 120,000 | 72" | x | 24" | 72" | 6 | 855/385 | 1080/486 |
|
|
|
|
|
|
|
|
|
115 volt, 50/60 Hz, 1 phase control circuit. ½ amp draw. Provided with 6' power cord with 3 prong plug.
NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.