Wolf IS15/S Integrated Electric Steamer Module, Planning Information, M O D E L I S 1 5 / S

Models: IS15/S

1 6
Download 6 pages 60.03 Kb
Page 5
Image 5
I N S T A L L A T I O N N O T E S

Planning Information

Integrated Electric Steamer Module

M O D E L I S 1 5 / S

I N S T A L L A T I O N N O T E S

This cooktop is intended for indoor use only. Refer to the illustrations and specifications for overall dimensions, cut-out dimensions and installation specifics.

Manual background Wolf recommends using 33" (838) wide cabinets for installation of two integrated modules side by side. An 18" (457) wide cabinet is recommended for installation of a single integrated cooktop module.

IMPORTANT NOTE: Review specific installation instructions for product to product capabilities

Manual background When multiple cooktops or modules are installed side by side, refer to the countertop cut-out dimensions on page 6.

This steamer module must be installed at least 15" (381) away from a Wolf fryer module, as contact between water and hot oil may cause burns from steam and hot oil.

Manual background A Wolf Cooktop or Pro ventilation hood is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. Also refer to the ventilation recommendation charts in the cooktop or Pro ventilation sections of our website, wolfappliance.com.

IMPORTANT NOTE: Wolf does not recommend the use of downdraft ventilation with the inte- grated steamer module.

The Wolf integrated steamer module requires

aseparate, grounded 3-wire 240/208 V AC, 60 Hz, 15 amp service with its own circuit breaker. It has a 4' (1.2 m) flexible 3-wire conduit for connection at the electrical supply. Locate electrical within the shaded area shown in the illustration on page 4.

Manual background You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

Manual background For the drain connection, the 5/8" (16) outlet from the valve will accept a drain hose that must flow downward to and tie into an existing sink drain, or a separate drain with a freefall may be installed. Following local building codes, your plumber will dictate how to plumb the unit. As a third option, the consumer will supply a heat resistant bucket for drainage in the location of the drain outlet. Refer to the illustration on page 4 for location of the drain outlet.

Manual background Refer to the installation instructions shipped with each Wolf product for detailed specifications.

This cooktop is intended for indoor use only.

Dimensions in parentheses are in

millimeters unless otherwise specified.

5

Page 5
Image 5
Wolf IS15/S dimensions Integrated Electric Steamer Module, Planning Information, M O D E L I S 1 5 / S