I N S T A L L A T I O N N O T E S

Planning Information

36" (914) Gas Cooktop

M O D E L C T 3 6 G

I N S T A L L A T I O N N O T E S

This cooktop is intended for indoor use only. Refer to the illustrations and specifications for overall dimensions, cut-out dimensions and installation specifics.

Manual background Wolf recommends using a 39" (991) wide cabinet with the 36" (914) gas cooktop.

Manual background A Wolf downdraft system, Cooktop or Pro ventilation hood is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. Also refer to the ventilation recommendation charts in the cooktop or Pro ventilation sections of our website, wolfappliance.com.

Manual background The Wolf 36" (914) gas cooktop requires a separate 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker and a grounded 3-prong receptacle should be located within the reach of the

6' (1.8 m) power cord. Locate electrical within the shaded area shown in the illustration on page 4.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Manual background Wolf gas cooktops are designed to operate on natural gas at 5" (12.5 mb) WC (water column) pressure or LP gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14"

(34.9 mb) WC; .5 psi (3.5 kPa). It is supplied with a 1/2" NPT male gas connection at the right rear bottom corner of the cooktop. The male connector exits the unit straight down and you are supplied with a regulator with two female connectors.

Manual background You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services.

Manual background Wolf gas cooktops using natural gas function up to an altitude of 8,000' (2438 m) without any adjustment. Natural gas installa- tions from 8,000' (2438 m) to 10,000' (3048 m) need the high altitude conversion kit. LP gas installations will operate up to 10,000' (3048 m) without adjustment.

Manual background When a gas cooktop is installed above cabinets, placement of the electrical and gas supply is not critical. A grounded outlet needs to be placed within 4' (1.2 m) of the right rear of the cooktop.

Manual background A Wolf built-in single oven may be installed below this cooktop. For this installation, the electrical and gas supply for the cooktop should be installed in the adjacent cabinet. Refer to page 6 for specifications. Be aware of the depth of the cooktop when planning for this installation.

IMPORTANT NOTE: When a built-in oven is installed below the cooktop, unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply be placed in an adjacent cabinet within reach of the conduit.

IMPORTANT NOTE: Wolf gas cooktops are designed and agency approved for installation with Wolf built-in ovens only.

Manual background When multiple cooktop units are installed side by side, refer to the countertop cut-out dimensions on page 7.

Manual background Refer to the installation instructions shipped with each Wolf product for detailed specifications.

This cooktop is intended for indoor use only.

Dimensions in parentheses are in

millimeters unless otherwise specified.