Wolf Appliance Company PW602718 Pro 27 686 Deep Wall Ventilation Hood, Planning Information

Models: PW602718

1 8
Download 8 pages 53.01 Kb
Page 5
Image 5
I N S T A L L A T I O N N O T E S

Planning Information

Pro 27" (686) Deep Wall Ventilation Hood

M O D E L P W 6 0 2 7 1 8 ( R )

I N S T A L L A T I O N N O T E S

millimeters unless otherwise specified. Refer to the illustrations and specifications for overall dimensions and installation specifics.

Manual background Wolf Pro wall ventilation hoods are recom- mended for use with any Wolf cooking appli- ance, and should be as least as wide as the cooking surface. It is recommended that the hood overlap the cooking surface by 3" (76) on either side.

IMPORTANT NOTE: For optimal performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle.

Manual background Installation of all Pro ventilation hoods should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration on page 4.

Manual background Wolf Pro wall hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for Pro ventilation recommendations and blower options.

IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower.

Manual background Pro wall hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker.

Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection.

Locate electrical within the shaded area shown in the Installation illustration on page 4.

Manual background You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

Manual background Refer to the installation instructions shipped with each Wolf product for detailed specifica- tions. This information can also be found on our website, wolfappliance.com.

Dimensions in parentheses are in

millimeters unless otherwise specified.

5

Page 5
Image 5
Wolf Appliance Company PW602718 Pro 27 686 Deep Wall Ventilation Hood, Planning Information, M O D E L P W 6 0 2 7 1 8 R