Planning Information
48" (1219) Gas Rangetops
M O D E L S R T 4 8 8 , R T 4 8 6 C , R T 4 8 6 G , R T 4 8 4 C G , R T 4 8 4 D G A N D R T 4 8 4 F
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf gas rangetop to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Be sure to follow minimum clearances established in the finished rough opening dimensions as shown in the illustration on page 4.
IMPORTANT NOTE: In
The platform for the rangetop must be 3/4"
(19)thick and include a
A Wolf Pro ventilation hood or hood liner is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. Also refer to the ventilation recommendation charts in the Pro ventilation section of our website, wolfappliance.com.
The Wolf gas rangetop requires a 110/120 V AC, 50/60 Hz electrical supply to operate the electronic ignition system. The 6' (1.8 m) power supply cord provided with the rangetop is equipped with a
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Wolf gas rangetops are designed to operate on natural gas at 5" (12.5 mb) WC (water column) pressure or LP gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa).
Wolf recommends the use of a 1/2" (13) I.D. commercial type flex hose; this is the minimum size that may be used. All plumbing to the flex hose must be 3/4" (19) minimum I.D. pipe.
IMPORTANT NOTE: A separate external gas
You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services.
Wolf gas rangetops using natural gas function up to an altitude of 8,000' (2438 m) without any adjustment. Natural gas and LP gas installations from 8,000' (2438 m) to 11,000' (3353 m) need the high altitude kit. Contact your Wolf dealer for details. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
Refer to the installation instructions shipped with each Wolf product for detailed specifications.
Dimensions in parentheses are in
millimeters unless otherwise specified. | 5 |