OPERATIONS
Emergency StopFigure 20. Digital display and key pad.
Figure 21. Table height handwheel.
When pushed, the emergency stop plate shown in Figure
19 stops the electricity to the motors and also applies
anair-discbraketostopthesanderimmediately.
To use the emergency stop, do these steps:
1. Pushthebottomoftheemergencystopplate.
2. Holdtheemergencystopplateuntilthesander has
come to a complete stop.
Figure 19. Emergency stop plate.
KEEP the sanding drum drive belts correctly adjusted.
Otherwise, the sanding drum pulley will slip when
the emergency brake is applied and not immediately
stop the machine in the event of an emergency!
Keypad and DisplayCalibrating the TableYou can push the UP or DOWN arrow keys to lift or
lower the table, or you can use the automated function
ofautoheightadjustmentforyournextsanding pass.
Allfunctionsarecontrolledthroughthekeypad andare
presented on the digital display. See Figure 20.
InputLED
Run
LED
Up and
Down
Keys
When you change the sandpaper or you notice an
inconsistency with the actual sanding thickness in
relationshiptoyourdigitalsetting,youmustre-calibrate
the table.
To re-calibrate your table, do these steps:
1. Sand a workpiece multiple times at the same
thickness until no sanding occurs when the
workpiece goes through the sander.
2. Using a caliper capable of measuring 0.001",
measure and record the workpiece thickness.
3. Type the recorded thickness of the workpiece on
the key pad, and the digital display will show the
thickness. Example: For 11⁄2"thickness,type1.500;
or for 13⁄8" thickness, type 1.375.
4. NowpressandholdtheSET key for 3 seconds:
The table is now calibrated.
Note: Holding the set key for 10 seconds toggles
the digital readout between metric and standard
measurements.