Xantech 48195D installation instructions Installation, Quick-Start, Remote Room Application

Models: 48195D

1 4
Download 4 pages 44.17 Kb
Page 4
Image 4

INSTALLATION

QUICK-START

A typical system will use an IR receiver, several emitters, and a power supply all connected to a connecting block.

1. Connect the IR receiver to the “IR RCVR” port on the connecting block. The ‘red’ connector is installed to the ‘red’ plug.

Note: In some extended distances, additional 3-conductor may be required and can be connected to the terminals on the connecting block.

2.Connect the Emitters to the connecting block. The ‘yellow’ connector is installed to the ‘yellow’ plug.

3.Connect the power supply to the connecting block.

4.Installation complete

REMOTE ROOM APPLICATION

One application is to locate the IR receiver in a remote room. This will give the end-user the ability to control audio/video equipment from a location where the remote control no longer has the ability of direct line-of-sight.

The IR receiver will need the 3.5mm stereo type mini plug removed to extend the wire run to the connecting block. A 3-terminal block is supplied to connect the IR receiver to the connecting block with a 3-conductor inter-room cable in between.

The 3-conductor inter-room cable (24 gauge up to 200’, 22 gauge up to 600’, 20 gauge up to 2000’, 18 gauge up to 5000’), is run to the main room.

Input connections must be made as illustrated. To extend the emitter wires to a more distant location, you may splice in 2-conductor wire, in the wire gauges mentioned before, as needed.