Xantech 490-85 KITRP manual Installation Instructions, Adjusting the IR Carrier Frequency, Step

Models: 490-85 KITRP

1 2
Download 2 pages 32.45 Kb
Page 2
Image 2
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

STEP 1:

Plug in the 2.1mm Coaxial power plug of the 781RG Power Supply (ITEM D) into the jack labeled 12VDC on the 789-44 Connecting Block (ITEM B).

Plug the AC end of the 781RG Power Supply (ITEM D) into an ‘un-switched’ 120V AC Line outlet.

STEP 2:

Plug the 3.5mm stereo mini plug from the 490-85 (ITEM A) into the IR RCVR input on the 789-44 Connecting Block (ITEM B).

STEP 3:

Plug in the 283M Emitters 3.5mm mono mini plug (ITEM C) into the jacks labeled EMITTERS on the 789-44 (ITEM B) and affix the opposite end of the IR Sensor Window of the controlled equipment.

490-85

 

 

Micro Link

781RG

 

LCD/CFL Friendly

 

Power Supply

Satellite Receiver

IR Receivers

 

 

To 120 V AC

 

 

(Unswitched)

 

Hand Held

789-44

283M Blink-IR™

Remote

VCR

 

Connecting Block

12VDC

STEP 1:Adjusting the IR Carrier FrequencyClock-wise (CW) will increase the carrier frequency. +12 VDC

GND

STATUS

Manual backgroundManual backgroundManual background IR IN

IR

RCVR

789-44CONNECTING BLOCK ®

EMITTERS

Manual background 283M Blink-IR™

AV Receiver

283M Blink-IR™

Mouse Emitter

MAIN ROOM

Adjusting the IR Carrier Frequency

Refer to the 490-85 instruction manual for more details. The 490-85 is factory set to an IR carrier repeat frequency of 38kHz. This will be correct for the majority of installations.

Clock-wise (CW) will increase the carrier frequency.

Counter-Clock-wise (CCW) will decrease the carrier frequency.

XANTECH CORPORATION

13100 Telfair Avenue

Sylmar, CA 91342

Phone 818-362-0353 Fax 818-362-9506

www.xantech.com

Part No. 08905114 Rev A 04-26-07

© 2007 Xantech Corporation

- 2 -

Page 2
Image 2
Xantech 490-85 KITRP manual Installation Instructions, Adjusting the IR Carrier Frequency, Step