Xantech installation instructions Model PA635

Models: PA635

1 20
Download 20 pages 55.82 Kb
Page 17
Image 17

Model PA635

Page 17

CAUTION: When making this connection, do not use the included 220 Ohm resistor! Refer also to CAUTION notes, Fig. 9.

When any one of the zones is turned ON, the common CO goes high (+12V), turning on power to the entire PA635. Similarly, when the last zone is turned OFF, the CO drops to 0 V, turning the PA635 totally OFF.

NOTE: No IR control of the PA635 is used in the system shown in Fig. 11. All volume, mute, etc. functions are handled by IR control of the ZPR68-10. The PA635 amplifier pairs are all set to the default volume level setting by pressing the LEVEL (System) RESET button (refer to item #9, Fig. 3).

AC Power Management of the entire system as shown in Fig. 11 is accomplished, therefore, as follows: a) The PA635 is controlled via the STATUS and CO functions as noted above.

The Source Components are controlled via the GATEKEEP-IRsensor system and the IR macros in the Smart Pads and, where used, IR macros in Learning Remotes (such as the Xantech URC types).

CAUTION: When powering up multiple PA635’s, a delay of 2 or more seconds should be incorporated between “power on” using multiple Xantech AC2’s.

© 2001 Xantech Corporation

Page 17
Image 17
Xantech installation instructions Model PA635