Installation
3–10 975-0127-01-01
Materials The following checklist is a general list of required materials.
Four corrosion-resistant fasteners sized #10 or larger for mounting the
inverter
Copper DC input cable as calculated in Table3-1 on page 3–7
Two 1/4 inch (6mm) ring terminals sized for the cable diameter to
connect the DC cables to the DC cabling terminal
Lugs and terminals to connect the DC cables that connect to the
battery, Disconnect/Battery Selector switch and fuse holder(s)
DC fuse(s) as calculated in “Calculating Fuse/Circuit Breaker Size”
on page 3–8 and fuse holder(s)
Copper chassis ground cable as calculated in Table3-2 on page 3–7
Ring terminal (appropriately sized to connect copper cable to chassis
ground screw) that meets the following specifications:
#10 screw
•UL/CSA approved
• copper
• tin-plated
Battery isolator (if connecting to a multiple-battery system)
Disconnect/Battery selector switch
Alternator controller1
High-output alternator1
1.Consult Appendix B, “Battery Types” and Appendix C, “Alternators and Charging
Systems” to determine whether you need these components.