Xantrex Technology 1750, 800 Troubleshooting Reference, PROWatt Series, Problem, Possible Cause

Models: 1500 800

1 2
Download 2 pages 49.95 Kb
Page 2
Image 2
PROWatt Series

PROWatt Series

Troubleshooting Reference

This section affects all the above mentioned PROWatt products.

Problem

Possible Cause

Solution

 

 

 

 

No output voltage; the

GFCI trip fault, i.e., the

1.

Remove any AC loads.

GFCI LED light is on.

ground fault trip circuit

2.

Press the Reset button on the GFCI.

 

has been activated.

If it trips again a ground fault is present.

 

 

3.

Turn the inverter off and inspect all wiring for ground

 

 

 

faults.

 

 

4.

Correct any wiring that could have caused the ground

 

 

 

fault before turning the inverter back on.

 

 

5.

Press the Reset button on the GFCI, restoring output

 

 

 

voltage.

 

 

 

 

No output voltage; the

GFCI end of life fault,

1.

Remove any AC loads.

GFCI LED light is on.

i.e., the GFCI has

2.

Press the Reset button on the GFCI.

 

permanently ceased to

If the Reset button continues to pop out after being pressed,

 

function.

3.

Turn the inverter off and inspect all wiring for ground

 

 

 

faults.

 

 

4.

Correct any wiring that could have caused the ground

 

 

 

fault before turning the inverter back on.

 

 

5.

Press the Reset button on the GFCI, restoring output

 

 

 

voltage.

If the above procedure fails to restore power at the AC outlets, the GFCI has reached its end of life.

6.Take the inverter to the place of purchase and have it serviced.

Trademarks PROWatt Series is a trademark of Xantrex International. Xantrex is a registered trademark of Xantrex International. Other trademarks, registered trademarks, and product names are the property of their respective owners and are used herein for identification purposes only.

Notice of Copyright PROWatt 800/1000/1500/1750 Owner’s Guide Addendum © August 2007 Xantrex International. All rights reserved.

Exclusion for Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. (“XANTREX”)

(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.

(B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USERS RISK; AND

(C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED XANTREX CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT WWW.XANTREX.COM.

Date and Revision August 2007 Rev A

Part Number 976-0159-01-01

Contact Information

 

Telephone:

1 800 670 0707 (toll free North America) 1 408 987 6030 (direct)

Fax:

1 800 994 7828 (toll free North America) 1 360 925 5143 (direct)

Email:

customerservice@xantrex.com

Web: www.xantrex.com

2

976-0159-01-01

Page 2
Image 2
Xantrex Technology 1750 Troubleshooting Reference, PROWatt Series, Problem, Possible Cause, Solution, Contact Information