Xantrex Alternator Regulator
Regulates 12 volt
Specifications
Output current | 6 A |
Available voltages | 12 V and 24 V |
Voltage regulation | |
Dimensions (H x W x D) | 4.9 x 3.25 x 1.5” |
Weight | 1 lb |
Warranty | One year |
Part number | |
| |
| |
| |
| |
Note: Specifications subject to change without notice. |
|
Primary Program Settings |
|
|
|
|
|
| Universal | Deep Cycle | Gell Cell | Absorbed Glass | Optima Sprial |
Mode | Factory Program | Flooded Lead Acid |
| Mat (AGM) | Wound |
Start Delay (seconds) | 45 | 45 | 45 | 45 | 45 |
Ramp Up (seconds) | 60 | 60 | 60 | 60 | 60 |
Bulk Voltage (maximum) | 14.1 | 14.6 | 14.1 | 14.4 | 14.6 |
Bulk Time (miminum) | 36 min. | 36 min. | 36 min. | 36 min. | 36 min. |
Absorption Voltage | 13.9 | 14.4 | 13.9 | 14.4 | 14.6 |
Absorption Time (minimum) | 0.2 hr. | 0.2 hr | |||
Float Voltage | 13.4 | 13.4 | 13.7 | 13.4 | 13.4 |
Float Time (maximum) | 6 hr. | 6 hr. | 6 hr. | 6 hr. | 6 hr. |
High Voltage Alarm | 15.2 | 15.6 | 15.1 | 15.4 | 15.6 |
Low Voltage Alarm | 12.8 | 12.8 | 12.8 | 12.8 | 12.8 |
Max. Battery Temperature | 125° F/52° C | 125° F/52° C | 125° F/52° C | 125° F/52° C | 125° F/52° C |
Max. Alternator Temperature | 225° F/107° C | 225° F/107° C | 225° F/107° C | 225° F/107° C | 225° F/107° C |
Equalization | Yes | Yes | No | Consult Mfg. | Consult Mfg |