HOW TO SET UP FUNCTIONS

 

 

 

 

 

 

 

When the FUNC light is on,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

you can access Advanced

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Functions of the Link 20.

 

 

i4.25

 

 

 

 

 

 

The values for each function

 

 

 

 

 

 

 

are changed using the SET

 

 

 

 

 

 

 

and SEL keys.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)Hold down the SET button until the numeric display says SEL.

2)Now press the SEL button 11 times F0i will appear in the display. You are now at F01 in the FUNCtion mode.

3)Press SEL again until the function you wish to set up appears.

4)Press the SET button to show the current value of the function you have selected.

5)To change the function value, press SET. The display will scroll through the range of available values. Stop scrolling when the value you wish appears in the display.

6)If you are only changing one function, simply leave the unit alone and in five seconds, the display will return to normal and the choice you have made for the function selected will be stored in memory.

7)If you wish to set up other functions, press the SEL button right away after making your selection in Step 5. You'll now scroll on to the next function, which can be changed the same way. When you have made all the changes desired, simply leave the unit alone for five seconds and the values will be memorized and the display returned to normal operation.

FUNCTIONS TABLE

The above section gave you the general approach to changing an Advanced Function setting. Now, we'll go through each of the Advanced Functions and explain what each does and how you may wish to use it. If you ever get "lost" and want to restore all factory default settings, simply follow the RESET procedure on page 25.

F01 - AUTO DISPLAY SCANNING

DEFAULT = OFF RANGE: OFF, ON

Automatically scans through the major displays, volts, amps, amp hours, and Time of Operation remaining. Each value is displayed for four seconds.

Scanning applies only to the battery selected with the BAT button.

16