SETUP & HISTORICAL DATA
The following table is a summary of the major values that may be changed through Setup or by accumulating historical data. The column on the right is provided to write down your setup values or historical data. Be sure and know these values before calling for customer service. Multiply values by two for
PARAMETER | DEFAULT | Bat. 1 | Bat.2 |
BATTERY VOLTSCHARGED | 13.2 V | _________ | ________ |
BATTERY AMPSCHARGED | 2% | _________ | ________ |
BATTERY CAPACITY | 200 Ah | _________ | ________ |
DATA | Bat. 1 | Bat.2 |
CEF | _________ | ________ |
# OF CEF RECALC'S | _________ | ________ |
AVG DEPTH OF DISCHARGE | _________ | ________ |
DEEPEST DEPTH OF DISCHARGE | _________ | ________ |
FUNCTIONS | DEFAULT | Bat. 1 | Bat.2 | |
DISPLAY SCAN | (F01) | Off | _________ | ________ |
DISPLAY SLEEP | (F02) | ON | _________ | ________ |
AMBIENT TEMP. (F03) | 70 °F | _________ | ________ | |
Ah/kWh | (F04) | Ah displayed | _________ | ________ |
ALT. ENERGY | (F05) | Off | _________ | ________ |
Manual CEF | (F06) | 95% This value should |
|
|
|
| only be set if you do NOT |
|
|
|
| want your Link 20 to |
|
|
|
| automatically calculate CEF _________ | ________ | |
TEMP. COEF. | (F07) | 0.5 | _________ | ________ |
PEUKERT EXP. | (F08) | 1.25 | _________ | ________ |
DISCH. FLOOR | (F09) | 100% | _________ | ________ |
BATTERY TYPE | (F10) | #1 LIQUID LEAD ACID | _________ | ________ |
SOFTWARE REV. (F15) | (Same for either battery) | _________ | ________ |
30