3.To remove the impeller, unscrew the central screw with a 7mm nut runner and remove it, place the screw to one side.
4.To clean the impeller, either wipe it with a damp, lint free cloth or wash it in warm soapy water. Do not use strong detergents or chemical cleaners.Thoroughly dry the impeller and refit. Replace the screw ensuring that it is securely fitted.
5.Clean the back draught shutter and grille in warm soapy water. Do not use strong detergents or chemical cleaners.
6.Thoroughly dry the back draught shutter and grille and refit the back draught shutter to the grille by placing into position and pushing down until it clicks into position, see Fig. G3 and Fig. G4.
7.Refit the back draught shutter/grille assembly by sliding the grille back over the release catches, the catches will locate and secure the grille.
Do not immerse the fan in water or other liquids to clean any other parts of the fan.
Never use strong solvents to clean the fan.
Apart from cleaning, no other maintenance is required.
Components, Fig. D.
1.Back draught shutter.
2.Fan assembly.
3.Outer grille.
4.Ladder strips.
5.Terminal cover.
6.Trickle vent catch.
7.Rear cable entry.
8.Top cable entry.
9.Rating plate.
10.Lugs for screw mounting.
11.Grille.
12.Screw hole caps.
13.Actuator lever.
Spares
40984SK – Wax Actuator
41004SK – Actuator Linkage Assy (GX6 EC2) 41010SK – Outer Grille Assembly 41785SK – Ladder Strip Kit 3”
41791SK – Cord Actuator Assy (GXC6 EC2) 41904SK – Impeller Assembly
41905SK – Front Cover Assembly 41906SK – GX6 EC2 Motor/Duct Assembly 41907SK – GXC6 EC2 Motor/Duct Assembly