5

Rear Panel

FILTER
CHANNEL B CHANNEL A
INPUT
CHANNEL B CHANNEL A
INPUT
CHANNEL B CHANNEL A
SPEAKERS
CHANNEL B
70V = 32/CHANNEL
100V = 64/CHANNEL
CHANNEL A
GG
OUTPUT VOLTAGE
CHANNEL B CHANNEL A
LOW CUT LOW CUT
40Hz 40Hz
OFF OFF80Hz 80Hz
HIGH CUT HIGH CUT
5kHz 5kHz
20 15
10
6
3
70V 100V
0
–dB
00
40
30
25
20 15
10
6
3
0
–dB
00
40
30
25
OFF OFF10kHz 10kHz
– –
+ +
+
+

56

13 42

2Volume controls (CHANNEL A, B)
These knobs enable you to adjust the output level of
Channels A and B in the range between dB and
0 dB.
3OUTPUT VOLTAGE switch
This switch toggles between 100 V and 70 V voltage
line.
4SPEAKERS terminals (CHANNEL A, B)
Barrier strip terminals are available. They are wired as
follows:
Hot (+), Cold (-)
Refer to Connecting speakers on page 6 for more
information on the impedance of the speaker systems
you can connect here.
5INPUT terminals (CHANNEL A, B)
Two types of balanced terminals for channels A and B
are provided.
XLR-3-31 type connector
They are wired as
follows (IEC 60268):
Pin 1ground
Pin 2hot
(
+
)
Pin 3cold
(
-
)
Barrier strip
Hot (+), Cold (-) and Ground (G).
6GND terminals
This is the grounding screw terminal. If hum or noise
occurs, ground (earth) the unit via this jack, or try
connecting it to the chassis of the mixer or preamp,
etc.
1FILTER switches (CHANNEL A, B)
Independent low-cut/high-cut filters are provided for
channels A and B. These filters allow you to change
cut-off frequencies.
LOW CUT switch
LOW CUT
40Hz
OFF 80Hz
80Hz......Cuts the frequency range of 80 Hz by
12 dB/octave.
Normally, use at this position.
40Hz......Cuts the frequency range of 40 Hz by
12 dB/octave.
Only use this position if you have verified
that the speaker transformer you will use
secures an adequate low-frequency charac-
teristic.
OFF .......Turns the low-cut filter off.
Only use this position if you have verified
that the signal input to the power amp has its
low frequencies cut.
Note: If low frequency is applied to the power amp,
the speakers, speaker transformers, and amp may be
damaged by speaker transformer core saturation.
HIGH CUT switch
HIGH CUT
5kHz
OFF 10kHz
10kHz....Cuts the frequency range of 10 kHz by
6 dB/octave.
5kHz......Cuts the frequency range of 5 kHz by 6 dB/
octave.
OFF .......Turns the high-cut filter off.
1
23
Cold
GroundHot