TROUBLESHOOTING

When generator engine fails to start after several attempts, or if no electricity is available at the output receptacles, check the possible causes in accordance with the following table. If your generator still fails to start or generate electricity, contact your nearest Yamaha dealer or authorized service center for further information or corrective procedures.

Possible causes

Problem

Starter will not run

Starter runs, but Engine will not start.

operation

Rotation decreased

Unstable rotation

 

During

Breaker turned off

Low power

The starter motor will not run :

Low battery

Blown fuse

Deteriorated fuel

Fuel piping

 

Clogging of Air cleaner

Clogging of Cooling air intake

Low oil level

Faulty spark plug

Overload by connected appliance

Incorrect or poor connection of wires

Insufficient capacity of extension cable

Carbon brushes are excessively worn

Leakage

Clogging

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

×× × × × × × × × × × × × × × × × × × × × × × × × × × × × ×

Wait for more than 0.5 second after the engine is stopped and then turn the starter switch to the "START" position.

If a remote control unit is connected, check if both starter switch on the control panel and the engine switch on the remote control unit are switched on.

The engine stopped and the oil pressure warning lamp flashed for three minutes. Check the following.

No fuel in the fuel tank ・・・・・・・・・Supply fuel

Fuel cock not open ・・・・・・・・・・・Turn on fuel cock

No sufficient engine oil ・・・・・・・・・Add or change engine oil

-35 -