TO REDUCE THE CHANCE OF ELECTRICAL SHOCK:
9Do not attempt to operate electric devices if the ground fault circuit interrupter reset button pops out repeatedly during use.
9Test the ground fault circuit interrupter during the
9Remember that only receptacle labeled “GFCI” have ground fault circuit interrupter protec- tion.
The G.F.C.I. (Ground Fault Circuit Interrupter) 1 shuts off power to the protected receptacles if a ground fault (electrical leak) is detected.
If the reset button 2 pops out 3, the electric devices connected into the receptacle may be faulty. If this happens, check the electric devices carefully. If the electric devices appears to be in good condition, press the reset button firmly until a click is heard. This will restore power. If the reset button pops out again, disconnect all the electric devices immediately. Have the electric devices inspected and repaired by a qualified repairperson before attempting to use them again.
Voltage select switch
cC
Do not operate the voltage select switch while the engine is running.
12
NO SWITCHING DURING OPERATION.
120/240V 120V
WHEN SWITCHING TO 120V. THE 120/240V OUTLET CANNOT BE USED.
1“120/240V”
When the voltage select switch is turned to “120/240V” 1, the generator supplies both 120V and 240V.
2“120V”
When the voltage select switch is turned to “120V” 2,