12

NO SWITCHING

DURING OPERATION.

120/240V 120V

WHEN SWITCHING TO 120V.

THE 120/240V OUTLET

CANNOT BE USED.

799-7CK

761-7CKa

AE00839

Connection

Alternating Current (AC)

w

Be sure any electric devices are turned off before plugging them in.

cC

9Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator.

9Be sure the total load is within generator rated output.

9Be sure the receptacle load current is within receptacle rated current.

9Do not operate the voltage select switch while the engine is running.

NOTE:

Make sure to ground (earth) the generator.

When the electric device is earthed, always the generator must be earthed.

1.Select the voltage select switch position according to the operating voltage of the electric device.

1120/240V

2 120V

2.Start the engine.

3.Plug in to AC receptacle.

GR

G X

NOTE:

To supply both 120V and 240V power sources from the 4-blade plug receptacle needs special knowledge

Y

120V

W

of the wiring plug. Please contact a trained electrician for the wiring of the plugs.

120V

240V

779-017a

– 21 –