AE00812

Application range

When using the generator, make sure the total load is within rated output of a generator. Otherwise, generator damage may occur.

AC

 

 

 

 

 

 

 

Power factor

1

0.8 ~ 0.95

0.4 ~ 0.75

(Efficiency 0.85)

 

 

 

 

 

 

 

EF6300iSDE

– 5,500W

– 4,400W

– 1,870W

 

 

 

 

1

763-7CKd

NOTE:

9“–” means below.

9Application wattage indicates when each device is used by itself.

9The overload indicator light 1 comes on when total wattage exceeds the application range. (See page 11 for more details.)

cC

9Do not overload. The total load of all electrical appliances must not exceed the supply range of the generator. Overloading will damage the generator.

9When supplying precision equipment, elec- tronic controllers, PCs, electronic computers, microcomputerbased equipment or battery chargers, keep the generator a sufficient dis- tance away to prevent electrical interference from the engine. Also ensure that electrical noise from the engine does not interfere with any other electrical devices located near the generator.

9If the generator is to supply medical equip- ment, advice should first be obtained from the manufacturer, a medical professional or hospi- tal.

9Some electrical appliances or general-purpose electric motors have high starting currents, and cannot therefore be used, even if they lie within the supply ranges given in the above table. Consult the equipment manufacturer for further advice.