24 EMX5016CF Owners Manual
Front & Rear Panels
Reference
XFRC MEASURE/CORRECT switch
FRC (Frequency Response Correction System) can
measure the frequency characteristics of the sound
field, and apply the correction curve to the GEQ auto-
matically. The MEASURE mode measures the fre-
quency characteristics, and the CORRECT mode
applies the correction curve to the GEQ according to
the measurement results. For details on using FRC,
refer to page 30.
MEASURE mode
There are two measurement methods: noise measure-
ment, engaged by pressing and holding the MEA-
SURE/CORRECT switch for two seconds or longer,
and music playback measurement, by pressing and
holding for three seconds or longer.
To measure the frequency characteristics by noise out-
put generated from the EMX, press and hold the MEA-
SURE/CORRECT switch for two to three seconds.
The indicator flashes quickly and the measurement
starts. The measurement result is updated on the GEQ
display every five seconds after measurement starts.
To measure the frequency characteristics by music
playback, such as from connected CD players, press
and hold the MEASURE/CORRECT switch for three
seconds or longer. The indicator flashes slowly and the
measurement starts. The measurement result is
updated on the GEQ display every five seconds after
measurement starts.
CORRECT mode
If you press and hold the MEASURE/CORRECT
switch for two seconds or longer after measurement,
the correction curve corresponding to the frequency
characteristics of the measurement result is applied to
the GEQ, and the indicator lights up. The correction
curve will be retained until the next measurement. If
you wish to recall the correction curve after turning off
the GEQ ON switch or power switch, press the MEA-
SURE/CORRECT switch again.
YVOCAL, DANCE, SPEECH Switches
Pressing either of these switches recalls the preset
GEQ settings. The GEQ display U indicates the set-
tings, and the switch indicator lights up. If you change
the GEQ settings after recall, the switch indicator turns
off. To restore the preset settings, press the switch
again.
ZUSER 1, USER 2, USER 3 Switches
These switches are used to store the GEQ settings in
each memory area and recall them.
Storing
Press and hold the USER switch for two seconds or
longer until the switch indicator flashes.
Recalling the stored settings
Press the USER switch to be recalled. The settings are
recalled and indicated on the GEQ display U, and the
switch indicator lights up. Pressing the GEQ +/–
switches to adjust the settings after recall turns off the
indicator. To restore the settings, press the USER
switch again.
After recalling the GEQ settings by pressing either of
the MEASURE/CORRECT, VOCAL, DANCE,
SPEECH, or USER switches, pressing the switch
again restores the GEQ settings before recall. This is
handy for comparing two GEQ settings.
bX\[aYZ]^
NOTE