■Word Clock
Sets whether the EX is used as the Word Clock
master or as a slave. “Word Clock” means
synchronization of the audio signal that passes
through digital devices. It is necessary to use Word
Clock when one or more digital audio devices are
connected for playback or recording.
When the EX is used as a master, the Word clock is
set at a sampling rate of 44.1kHz. When the EX is
used as a slave, the Word Clock automatically
changes to the clock received at WORD CLOCK IN
(WORD CLOCK IN: separately sold EXDGO1 jack).
❏ Settings: internal (EX = master), external (EX = slave)
This “Word Clock” parameter is not displayed or
selected unless you install an optional EXDGO1 Digital
Output Board.
For the EX to output a digital signal, it is necessary to
install the separately sold EXDGO1 (Digital Output
Board).
When receiving word clock from an external audio
device, you will need to connect the EXDGO1 (Word
Clock In [BNC] jack) and the external audio device. In
this case, use the BNC connector/coaxial cable with the
impedance characteristics, 75Ω.
[F7]: MSG (Greeting Message)
Sets the message that will be momentarily displayed in
the screen when the power is turned on. The message
can be up to a maximum of 20 characters.
For more information or how to input characters, see page
79.
277
Utility Mode
Utility/E/qx 5/21/98 11:55 AM Page 277