10
Air Flow
This unit uses a forced cooling system in which air comes in through the front opening and goes out the rear.
4-6.5 x 11
88
463
480
Unit : mm
248
4-C15
4-ø4.5
76.2
71.5±0.1
71.5±0.1
78
78
Fan kit
PC9500N/
PC4800N
PC9500N/
PC4800N
Rack Mounting
If multiple high-power amp units are mounted in a rack with poor ventilation, the heat from the amps will cause the
interior of the amp to become very hot, causing the performance of the amps to be impaired. In particular, when
mounting in a rack whose back can not be left open, mount according to the following instructions.
Rack: Leave a gap of 10 cm or more between the rear panel of the rack and the rear panel of the amplifier.
Fan: Use a fan with 1.5 m3/min or more maximum wind and 5 mmH2O or more maximum static pressure.
Mounting:Install the fan kit on the top slot or the top panel of the rack and install a blanking panel between two
amps.
If the unit is rack mounted and transported frequently, we recommend that the rear of the unit be supported by fitting
a pair of metal brackets, one each side.
Example of mounting
The figure on the left below shows an example of a fan kit (panels and two fans) on the top slot of the rack. The fans
are Minebia 3115PS-12T-B30 (with 0.9 m3/min maximum wind and 5 mmH2O maximum static pressure).
The figure on the right below is a dimensional diagram of a panel on which two 3115PS-12T-B30 are installed.
Side View Rear View
Air intake Air exhaust
Front