14 XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual
* These specifications apply to rated power supplies of 120V, 230V and 240V.
0 dBu=0.775 Vrms, Half Power=1/2 Output Power (3 dB below rated power)
Specifications and descriptions in this owner’s manual are for information pur-
poses only.
Yamaha Corp. reserves the right to change or modify products or specifica-
tions at any time without prior notice. Since specifications, equipment or
options may not be the same in every locale, please check with your Yamaha
dealer.
European models
Purchaser/User Information specified in EN55103-1 and EN55103-2.
Inrush Current: XP7000/5000 32A , XP3500 65A, XP2500 55A, XP1000 15A
Conforms to Environments: E1, E2, E3 and E4
All Models
Power Bandwidth Half Power, THD+N= 0.5 % MIN 10 Hz-40 kHz
THD+N 20 Hz–20 kHz, Half Power MAX 0.1 %
Intermoduration Distortion 60 Hz:7 kHz, 4:1, Half Power MAX 0.1 %
Frequency Response RL=8 Ω, Po=1 W, HPF=OFF
20 Hz-50 kHz
MAX 0 dB
TYP 0 dB
MIN -1 dB
Channel Separation Half Power, RL=8 Ω, 1 kHz,
Att. max, input 600 Ω shunt MIN 70 dB
Residual Noise 20 Hz–20 kHz, Att. min,
(DIN AUDIO) MAX -70 dBu
Damping Factor RL=8 Ω, 1 kHz MIN 350 (XP7000, XP5000), 200 (XP3500, XP2500, XP1000)
Voltage Gain Att. max TYP Selectable from 32 dB or 26 dB (or +4 dBu input sensitivity) by select switch
Input Sensitivity (dBu) Att. max, Rated Power 8 ΩXP7000 XP5000 XP3500 XP2500 XP1000
Switch Position +4 dBu +4 +4 +4 +4 +4
26 dB +13.7 +12.2 +10.7 +9.2 +5.2
36 dB +7.7 +6.2 +4.7 +3.2 -0.8
Maximum Input Voltage MIN +22 dBu
Input Impedance TYP 20 kΩ (balanced), 10 kΩ (unbalanced)
Controls Front Panel POWER switch (push on/push off)
attenuator (31 position) x 2
Rear Panel MODE switch (STEREO/BRIDGED/PARALLEL) x 1
HPF switch (20 Hz/55 Hz/OFF 12 dB/oct) x 2
GAIN SELECT switch (32 dB/26 dB/+4 dBu) x 1
Connectors Input XLR-3-31 type/ch, Euroblock connector (balanced) /ch
Output SPEAKON/ch, 5 way binding post x 1
MONITOR/REMOTE Dsub 15 P x 1
Indicators POWER/STANDBY x 1 (Green/Orange)
SIGNAL x 2 (Green)
CLIP/LIMIT x 2 (Red)
PROTECTION/TEMP x 1 (Red)
x 1 (Red) heatsink temp ≥ 85 °C
Load Protection POWER switch on/off mute
DC-fault:
power supply shutdown/operation not restored automatically. (XP7000, XP5000)
output relay off/restored automatically. (XP3500, XP2500, XP1000)
Clip limiting : THD ≥ 0.5 %
Amplifier Protection Thermal:
Cuts the output (heatsink temp ≥ 90 °C) ; operation not restored automatically.
VI limiter (RL ≤ 1 Ω): Limit the output.
Power Supply Protection Thermal:
Power supply shutdown (heatsink temp ≥ 100 °C) ; operation not restored auto-
matically. (XP7000, XP5000).
power supply shutdown (transfomer temp ≥ 130 °C)
; restored automatically. (XP3500, XP2500, XP1000)
Cooling Variable-speed fan: x 1(XP3500, XP2500, XP1000), x 2 (XP7000, XP5000)
Fan stop at heatsink temp < 55 °C
Power Requirements UC: 120 V/60 Hz
HB: 230 V/50 Hz
A: 240 V/50 Hz
Dimensions (W x H x D) 480 x 88 x 456 mm
Weight XP7000
14 kg
XP5000
14 kg
XP3500
15 kg
XP2500
14 kg
XP1000
12 kg
Included Accessories Security cover (with a hex wrench), Owner’s Manual