York 110, 114, 218, 112, 216 dimensions Compatibility Options / Accessories / Models

Models: 216 112 218 110 114

1 6
Download 6 pages 22.7 Kb
Page 6
Image 6
Compatibility Options / Accessories / Models

Compatibility tables for FCU

LASER and LOW BODY

Compatibility Options / Accessories / Models

 

 

 

 

 

 

STANDARD

 

 

 

 

LOW BODY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LASER

 

 

CONCEALED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

designation

YLV

YLH

 

YLV-AF

YLH-AF

YLIV

YLIH

 

YLIV-AF

YLIH-AF

YLVR

YLIVR

Coils and heaters**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BA1**

Additionnal 1 row heating

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KREL**

Kit electrical heater with safety thermostat and relay

l

l

 

l

l

l

l

 

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory fitted thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSL00

Fan speed selector (buit in)

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CML00

Thermostat with manual fan speed and S/W change

 

 

 

 

 

 

 

 

 

 

l

l

over (buit in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CEL00

Thermostat with manual fan speed, dead band,

 

 

 

Compatible with electrical heaters

 

 

l

l

automatic change over (buit in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CEL20

Thermostat with automatic fan speed, dead band,

 

 

 

Compatible with electrical heaters

 

 

l

l

automatic change over (buit in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CEL30

Thermostat with automatic fan speed, dead band,

 

 

 

 

 

 

 

 

 

 

l

l

automatic change over for modulating valves (buit in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote controllers and thermostats

 

 

 

 

 

 

 

 

 

 

 

 

CSR00

Fan speed selector (wall mounted)

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CMR00

Thermostat with manual fan speed and S/W change

 

 

 

 

 

 

 

 

 

 

l

l

over (wall mounted)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CER00

Thermostat with manual fan speed, dead band,

 

 

 

Compatible with electrical heaters

 

 

l

l

automatic change over (buit in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CER20

Thermostat with automatic fan speed, dead band,

 

 

 

Compatible with electrical heaters

 

 

l

l

automatic change over (buit in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CER30

Thermostat with automatic fan speed, dead band,

 

 

 

 

 

 

 

 

 

 

l

l

automatic change over for modulating valves (buit in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CBL20

Parallel connection for ON/OFF valve

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CBL30

Parallel connection for modulating valve

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory fitted)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3A2 (2p)

3-way 4-ports on/off valves for 2-pipe systems

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3A2 (4p)

3-way 4-ports on/off valves for 4-pipe systems

l

l

 

l

l

l

l

 

l

l

l

l

J3AM (2p)

3-way 4-ports modulating valves for 2-pipe systems

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3AM (4p)

3-way 4-ports modulating valves for 4-pipe systems

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DT (2p)

Shut-off valves for 2-pipe systems

l

l

 

l

l

l

l

 

l

l

l

l

(in addition to J3A2/J3AM valves)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DT (4p)

Shut-off valves for 4-pipe systems

l

l

 

l

l

l

l

 

l

l

l

l

(in addition to J3A2/J3AM valves)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC

Condensate pump

l

l

 

l

l

l

l

 

l

l

l

l

WS

Water sensor

 

 

 

 

 

Compatible with CEL/CER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM

Minimum temperature thermostat

l

l

 

l

l

l

l

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feets and panels

CP1

Set of painted feet

l

 

 

 

l

ZL1

Set of feet + frontal socle

l

 

 

 

l

PPV1

Vertical painted back panel

l

 

l

 

 

PPH1

Horizontal painted back panel

 

l

 

l

 

 

 

 

 

 

 

 

External air intake

l

PA

Air intake plenum

 

 

 

 

 

l

 

 

PAS

Air intake plenum collars

 

 

 

 

 

l

 

 

PA90°

90° air intake plenum

 

 

 

 

 

l

 

 

RCA

Air intake duct fitting

 

 

 

 

 

l

 

 

PM

Air delivery plenum with collars

 

 

 

 

l

l

l

l

PM90

90° air delivery plenum

 

 

 

 

l

l

l

l

 

 

 

 

 

 

 

 

 

 

lCompatible

Compatible with conditions

Not compatible

**Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater.

l

l

Page 6
Image 6
York 110, 114, 218, 112, 216 Compatibility Options / Accessories / Models, Compatibility tables for FCU LASER and LOW BODY