York DH 078, 90, 102 manual Predator, General, Description

Models: 102 90 DH 078

1 48
Download 48 pages 31.76 Kb
Page 46
Image 46

246646-YTG-C-0606

GUIDE SPECIFICATIONS

PREDATOR®

DH 078, 090, 102, 120 & 150, 11.5 EER

GENERAL

Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. YORK® Predator® units are convertible single packages with a com- mon footprint cabinet and common roof curb for all 6-1/2 through 12-1/2 ton models. All units have two compressors with independent refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial appli- cations and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factory-installed options or field-installed accessories.

of the coils. Condensate pan shall be slide out design, con- structed of a non corrosive material, internally sloped and conforming to ASHRAE 62-B9 standards. Condensate con- nection shall be a minimum of ¾” I.D. female and be rigid mount connection.

INDOOR (EVAPORATOR) FAN ASSEMBLY

Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Job site selected brake horsepower shall not exceed the motors nameplate horsepower rating plus the service factor. Units shall be designed to operate within the service factor. Fan wheel shall be double inlet type with for- ward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no mainte- nance. Entire blower assembly and motor shall be slide out design.

OUTDOOR (CONDENSER) FAN ASSEMBLY

DESCRIPTION

Units shall be factory assembled, single package, (Elec/Elec, Gas/Elec), designed for outdoor installation. Units shall have a minimum EER of 9.0. They shall have built in field convert- ible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with fac- tory installed options or field installed accessories. The units shall be factory wired, piped and charged with R-22 refriger- ant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. The cooling performance shall be rated in accordance with DOE and ARI test proce- dures. Units shall be CSA certified to ANSI Z21.47 and UL 1995/CAN/CSA No. 236-M90 standards.

UNIT CABINET

Unit cabinet shall be constructed of G90 galvanized steel with exterior surfaces coated with a non-chalking, powder paint finish, certified at 1000 hour salt spray test per ASTM-B117 standards. Indoor blower sections shall be insulated with up to 1” thick insulation coated on the airside. Aluminum foil faced insulation shall be used in the unit’s compartments and be fastened to prevent insulation from entering the air stream. Cabinet doors shall be hinged with toolless access for easy servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. Disposable 2” filters shall be furnished and be accessible through hinged access door. Fan perfor- mance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating bypass

The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically bal- anced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning.

REFRIGERANT COMPONENTS

Compressors:

A.Shall be fully hermetic type, direct drive, internally pro- tected with internal high-pressure relief and over temper- ature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or – 10% of the unit nameplate voltage.

B.Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting.

Coils:

A.Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option.

B.Evaporator and condenser coils shall be of the direct expansion, draw-thru design.

46

Unitary Products Group

Page 46
Image 46
York DH 078, 90, 102 manual Predator, General, Description

102, 90, DH 078 specifications

York DH series chillers, specifically models 078, 90, and 102, are recognized in the HVAC industry for their advanced features, efficiency, and reliability. These chillers are designed to provide exceptional cooling performance for commercial and industrial applications, prioritizing energy efficiency and sustainability.

One of the standout features of the York DH series is its dual-compressor system. This design not only enhances reliability but also contributes to energy savings by allowing the unit to operate at varying loads more effectively. This adaptability ensures that the chillers can maintain optimal performance even during fluctuating demand, reducing energy consumption and associated costs.

The DH series chillers employ a microchannel condenser technology that maximizes heat exchange efficiency. This technology reduces the amount of refrigerant required while also minimizing the footprint of the unit, offering significant advantages in space-constrained environments. Additionally, microchannel coils are less susceptible to corrosion, enhancing the longevity and reliability of the chillers.

Another notable feature is the use of variable-speed drives (VSD) in the compressor system. These drives allow for precise control of the compressor speed, enabling the chillers to adjust to the cooling demands dynamically. This flexibility not only enhances the overall efficiency of the system but also contributes to quieter operation, making the chillers suitable for environments where noise levels are a concern.

York's DH series also integrates advanced controls and monitoring capabilities. The intuitive control system allows for easy programming and operation, providing users with real-time data on system performance and diagnostics. This feature aids in maintenance and troubleshooting, reducing downtime and ensuring that the chillers operate at peak efficiency.

Safety is paramount in the design of the York DH chillers. Each model is equipped with multiple safety features, including pressure relief valves and temperature monitoring systems, to protect the unit during operation. This commitment to safety not only safeguards the equipment but also ensures compliance with industry standards.

In conclusion, the York DH 078, 90, and 102 chillers exemplify modern HVAC technology with their dual-compressor systems, microchannel condenser technology, variable-speed drives, and advanced control systems. These features combine to deliver efficient, reliable, and sustainable cooling solutions for a wide variety of applications. The York DH series represents a significant advancement in chiller design and functionality, making it a preferred choice for many professionals in the field.