York AHP18 YTG-M-0610, Min. Circuit Ampacity, Max. O.C.P.1 Amps/Type, 75C Wire Size - AWG

Models: AHP18

1 12
Download 12 pages 36.43 Kb
Page 8
Image 8
Min. Circuit Ampacity

 

 

 

 

 

 

 

255029-YTG-M-0610

ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE 208/230-1-60

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater

 

 

Field Wiring

 

 

 

Heater

 

 

 

 

 

 

Models

Amps

Min. Circuit Ampacity

Max. O.C.P.1 Amps/Type

75°C Wire Size - AWG

Models*

 

240V

 

 

 

 

 

 

 

 

208V

240V

208V

240V

208V

240V

 

 

 

 

 

 

 

 

 

 

 

 

 

4HK*6500206

10.4

13.5

15.4

15

20

12

12

AHP18B**H21

 

 

 

 

 

 

 

 

4HK*6500506

20.0

23.8

27.4

25

30

10

10

 

 

 

 

 

 

 

 

 

 

4HK*6500806

31.3

36.0

41.5

40

45

8

8

 

 

 

 

 

 

 

 

 

 

4HK*6500206

10.4

13.0

14.9

15

15

12

12

 

 

 

 

 

 

 

 

 

 

4HK*6500506

20.0

23.4

26.9

25

30

10

10

AHP24B**H21

 

 

 

 

 

 

 

 

4HK*6500806

31.3

35.6

41.0

40

45

8

8

 

 

 

 

 

 

 

 

 

 

4HK*6501006

40.0

45.1

51.9

45

60

8

6

 

 

 

 

 

 

 

 

 

 

4HK16501306

54.2

60.4

69.6

70

70

4

4

 

 

 

 

 

 

 

 

 

 

4HK*6500506

20.0

24.2

27.8

25

30

10

10

 

 

 

 

 

 

 

 

 

 

4HK*6500806

31.3

36.4

41.9

40

45

8

8

AHP30B**H21

 

 

 

 

 

 

 

 

4HK*6501006

40.0

45.8

52.8

50

60

8

6

 

 

 

 

 

 

 

 

 

 

4HK16501306

54.2

60.1

70.5

70

90

4

3

 

 

 

 

 

 

 

 

 

 

4HK165N1506

60.0

67.5

77.8

70

90

4

3

 

 

 

 

 

 

 

 

 

 

4HK*6500506

20.0

25.8

29.5

30

30

10

10

 

 

 

 

 

 

 

 

 

 

4HK*6500806

31.3

38.0

43.6

40

45

8

8

AHP36C**H21

 

 

 

 

 

 

 

 

4HK*6501006

40.0

47.5

54.5

50

60

8

6

 

 

 

 

 

 

 

 

 

 

4HK16501506

60.0

69.1

79.5

70

90

4

3

 

 

 

 

 

 

 

 

 

 

4HK16501806

73.3

83.6

96.1

90

100

3

3

 

 

 

 

 

 

 

 

 

 

4HK*6500506

20.0

25.9

29.8

30

30

8

8

 

 

 

 

 

 

 

 

 

 

4HK*6500806

31.3

38.1

43.9

40

45

8

8

 

 

 

 

 

 

 

 

 

AHP42C**H21

4HK*6501006

40.0

47.6

54.8

50

60

6

6

 

 

 

 

 

 

 

 

4HK16501506

60.0

69.3

79.8

70

90

4

3

 

 

 

 

 

 

 

 

 

 

 

4HK16501806

73.3

83.7

96.4

90

100

3

3

 

 

 

 

 

 

 

 

 

 

4HK16502006

80.0

90.9

104.8

100

110

3

2

 

 

 

 

 

 

 

 

 

 

4HK*6500506

20.0

25.9

29.8

30

30

10

10

 

 

 

 

 

 

 

 

 

 

4HK*6500806

31.3

38.1

43.9

40

45

8

8

 

 

 

 

 

 

 

 

 

AHP48D**H21

4HK*6501006

40.0

47.6

54.8

50

60

8

6

 

 

 

 

 

 

 

 

4HK16501506

60.0

69.3

79.8

70

90

4

3

 

 

 

 

 

 

 

 

 

 

 

4HK16501806

73.3

83.7

96.4

90

100

3

3

 

 

 

 

 

 

 

 

 

 

4HK16502006

80.0

90.9

104.8

100

110

3

2

 

 

 

 

 

 

 

 

 

 

4HK*6500506

20.0

31.2

34.5

35

35

8

8

 

 

 

 

 

 

 

 

 

 

4HK*6500806

31.3

43.4

48.6

45

50

8

8

 

 

 

 

 

 

 

 

 

 

4HK*6501006

40.0

52.8

59.5

60

60

6

6

AHP60D**H21

 

 

 

 

 

 

 

 

4HK16501506

60.0

74.5

84.5

90

90

3

3

 

 

 

 

 

 

 

 

 

 

4HK16501806

73.3

88.9

101.1

90

110

3

2

 

 

 

 

 

 

 

 

 

 

4HK16502006

80.0

96.2

109.5

100

125

3

1

 

 

 

 

 

 

 

 

 

 

4HK16502506

100.0

117.8

134.5

125

150

1

1/0

 

 

 

 

 

 

 

 

 

1.O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. * May be 0 (no breaker) or 1 (with breaker).

8

Johnson Controls Unitary Products

Page 8
Image 8
York AHP18 specifications YTG-M-0610, Min. Circuit Ampacity, Max. O.C.P.1 Amps/Type, 75C Wire Size - AWG