ACCESSORIES

ACCESSORIES

Refer to Price Manual for specific model numbers.

Compressor Blanket - Designed to further reduce the nor- mal operating sound and is required to meet Canadian sound levels for units of three tons and below.

Refer to Price Manual for specific model numbers.

Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.

TXV KIT - 1TVM series TXV’s must be used to obtain system performance. See Tabular Data Sheet for proper selection.

332018-BTG-D-0208

ROOM THERMOSTATS - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation.

1H/1C, manual changeover electronic non-programmable thermostat.

1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat.

1H/1C, auto/manual changeover, electronic programmable.

*For the most current accessory information, refer to the price book or consult factory.

SOUND POWER RATINGS*

UNIT MODEL

(dBA)

024

75

 

 

030

76

 

 

036

76

 

 

042

76

 

 

048

76

 

 

060

76

 

 

* Rated in accordance with ARI 270-95 Standards.

TYPICAL INSTALLATION

 

MINIMUM 18” SERVICE ACCESS

THERMOSTAT

TO FURNACE OR

60” OVERHEAD

CLEARANCE ON ONE SIDE

 

 

AIR HANDLER

CLEARANCE

WEATHERPROOF

 

 

TERMINAL BLOCK

 

DISCONNECT

 

 

 

 

 

SWITCH

 

NEC CLASS 1 WIRING

 

 

 

NEC CLASS 2 WIRING

10” CLEARANCE

 

 

TO INDOOR COIL

COIL AREA

 

 

NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.

SEAL OPENING(S) WITH

PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

TYPICAL FIELD WIRING

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

POWER WIRING

24 VOLT CONTROL WIRING

 

CONTROL WIRING

MINIMUM 18 GA. WIRE

 

 

 

 

FACTORY WIRING

(NEC CLASS 2)

 

 

 

 

 

 

FURNACE OR AIR HANDLER TERMINAL BLOCK

CONTACTOR

TERMINALS

GND.

LUGCOIL

CONDENSING UNIT

C Y R G W

* TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

*

Y R G W

ROOM THERMOSTAT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.