R407C
Window
Y9USC/E 09 / 12 / 18 B5A Y9USC/E 09 / 12 / 18 B5R
Technical features
Models |
| Sizes | Y9USC 09 B5A | Y9USC 12 B5A | Y9USC 18 B5A | Y9USE 09 B5A | Y9USE 12 B5A | Y9USE 18 B5A | |||
|
|
|
|
|
|
|
|
|
| ||
| Y9USC 09 B5R | Y9USC 12 B5R | Y9USC 18 B5R | Y9USE 09 B5R | Y9USE 12 B5R | Y9USE 18 B5R | |||||
|
|
| |||||||||
|
|
|
|
|
|
|
|
| |||
Cooling capacity |
| kW | 2.6 | 3.5 | 5.3 | 2.6 | 3.5 | 5.3 | |||
|
|
|
|
|
|
|
|
| |||
Heating capacity |
| kW | - | - | - | 2.6 | 3.5 | 5.3 | |||
|
|
|
|
|
|
|
|
|
|
|
|
Power supply |
| V/Ph/Hz |
|
| 230 / 1 / 50 + E |
|
|
|
|
| |
Refrigerant |
| Type |
|
| R407C |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
Power input (cooling / heating) | kW | 1.0 / - | 1.3 / - | 2.1 / - | 1.0 | / 0.9 | 1.3 | / 1.2 | 2.1 | / 1.9 | |
|
|
|
|
|
|
|
|
|
|
|
|
Operating current | (cooling / heating) | A | 4.6 / - | 6.1 / - | 9.6 / - | 4.6 | / 4.3 | 6.1 | / 5.7 | 9.6 | / 8.9 |
|
|
|
|
|
|
|
|
|
|
|
|
EER / COP |
| W / W | 2.6 / - | 2.6 / - | 2.5 / - | 2.6 | / 2.8 | 2.6 | / 2.8 | 2.5 | / 2.7 |
|
|
|
|
|
|
|
|
| |||
Indoor airflow |
| m3/h | 360 | 530 | 750 | 360 | 530 | 750 | |||
|
|
|
|
|
|
|
| ||||
Refrigerant charge | g | 510 | 870 | 870 | 550 | 900 | 1 150 | ||||
|
|
|
|
|
|
|
|
|
|
| |
Sound pressure at 1 m (H / L) | dB(A) | 47 / 43 | 46 / 42 | 52 / 47 | 47 | / 43 | 46 | / 42 | 52 | / 47 | |
Net dimensions W / H / D | mm | 450 / 346 / 535 | 560 / 400 / 650 | 660 / 435 / 650 | 450 / 346 / 535 | 560 / 400 / 650 | 660 / 435 / 650 | ||||
|
|
|
|
|
|
|
| ||||
Packing dimensions W / H / D | mm | 495 / 435 / 580 | 620 / 445 / 770 | 740 / 520 / 750 | 495 / 435 / 580 | 620 / 445 / 770 | 740 / 520 / 750 | ||||
|
|
|
|
|
|
|
|
| |||
Net weight |
| kg | 35 | 48 | 55 | 37 | 54 | 59 | |||
|
|
|
|
|
|
|
|
| |||
Gross weight |
| kg | 39 | 53 | 60 | 41 | 59 | 64 | |||
|
|
|
|
|
|
|
|
| |||
Applicable area |
| m2 | |||||||||
Stuffing quantity | 20’ / 40’ HQ | Set | 220 / 574 | 133 / 340 | 94 / 240 | 220 | / 574 | 133 | / 340 | 94 / 240 |
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
|
|
|
|
|
|
|
|
|
|
|
|
|
Super compact | Quiet design |
| Easy removed |
| Fresh air switch |
| Sliding chassis |
| Two drainage |
|
| |
design |
|
| panel |
|
|
|
|
| methods |
| system |