RANGE
COMPOSITION
N 700: a range of over 100 models for the professional caterer designed to guarantee the highest level of performance, reliability, energy saving, safety standards and ergonomic operation. These concepts are reflected in the total modularity of the range that ensures numerous configurations, either
178018
N 700
ELECTRIC BOILING TOPS ZANUSSIP R O F E S S I O N A L
FUNCTIONAL AND
CONSTRUCTION
FEATURES
�
�Hot plates with a power of 2,6 kW.
�Worktop in 1,5mm stainless steel.
Front panel in stainless steel with | TECHNICAL DATA |
|
|
|
|
|
| |
CHARACTERISTICS |
|
| MODELS |
|
| |||
Scotch Brite finish. |
|
|
|
| ||||
� All models have |
| KCE400 | KCE4002 | KCE800 | KCE8002 | KCEQ800 | KCEQ8002 | |
| 178013 | 178035 | 178014 | 178036 | 178018 | 178027 | ||
edges to allow |
|
|
|
|
|
|
| |
Power supply | Electric | Electric | Electric | Electric | Electric | Electric | ||
between units, eliminating gaps and |
|
|
|
|
|
|
| |
External dimensions - mm |
|
|
|
|
|
| ||
possible dirt traps. | width | 400 | 400 | 800 | 800 | 800 | 800 | |
� The special design of the control | depth | 700 | 700 | 700 | 700 | 700 | 700 | |
knob system guarantees against | height | 250 | 250 | 250 | 250 | 250 | 250 | |
Back plate dimensions - mm | Ø 230 | Ø 230 | Ø 230, Ø | Ø 230, Ø | Ø 230, Ø | Ø 230, Ø | ||
water infiltration. | ||||||||
|
|
| 230 | 230 | 230 | 230 | ||
� IPX4 water protection. |
|
|
|
|
|
|
| |
Back plates power - kW | 2.6 | 2.6 | 2.6, 2.6 | 2.6, 2.6 | 2.6, 2.6 | 2.6, 2.6 | ||
� Main connections can be via the |
|
|
|
|
|
|
| |
Front plates dimension - mm | Ø 230 | Ø 230 | Ø 230, Ø | Ø 230, Ø | Ø 230, Ø | Ø 230, Ø | ||
rear or the base of the unit. |
|
|
| 230 | 230 | 230 | 230 | |
� All models can be easily mounted | Front plates power - kW | 2.6 | 2.6 | 2.6, 2.6 | 2.6, 2.6 | 2.6, 2.6 | 2.6, 2.6 | |
on open base cupboards or bridging | Power - kW |
|
|
|
|
|
| |
5.2 | 5.2 | 10.4 | 10.4 | 10.4 | 10.4 | |||
supports. | ||||||||
Net weight - kg. | 20 | 20 | 40 | 40 | 40 | 40 | ||
� All top models provided with | ||||||||
Supply voltage | 400 V, | 230 V, 3, | 400 V, | 230 V, 3, | 400 V, | 230 V, 3, | ||
service duct to facilitate installation. |
| 3N, | 50/60 | 3N, | 50/60 | 3N, 50/60 | 50/60 | |
|
| 50/60 |
| 50/60 |
|
|
| |
| Square plate |
|
|
|
| • | • |