INSTALLATION
Securing The Oven To The Cabinet
Fit the appliance into the cabinet recess, open the oven door and secure the oven to the kitchen cabinet with four wood screws, which fit the holes provided in the oven frame (Fig. 3).
FO 0143 | Fig. 3 |
|
ELECTRICAL CONNECTION
The oven designed to be connected to 240V (50Hz) electricity supply.
The oven has an easily accessible terminal block which is marked as follows:
"L" Live terminal "N" Neutral terminal
Earth terminal
plate at the back of the oven to reach the terminal block. Connect the brown insulated wire to the terminal marked "L".
Connect the blue insulated wire to the terminal marked "N". Connect the green and the yellow insulated wire to the
terminal marked |
| . | ||||||
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tighten the cable clamps ensuring that there is no strain on the mains terminal.
Replace the cover and tighten securing screws.
THIS APPLIANCE MUST BE EARTHED
The cable used to connect the oven to the electrical supply should have the characteristics indicated in the table.
If you require a direct connection to the electric network (mains), it is necessary that you install an omnipole switch between the appliance and the mains, with a minimum gap of 3 mm between the switch contacts and a type suitable for the required lead in compliance with the current rule.
This switch must be easily accessible to the user on completion of the installation and must not break the yellow and green earth cable at any point.
In order to connect the oven it is necessary to remove the
FOR UK USE ONLY
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.
Before the appliance is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should these safety measures not be carried out. This appliance meets the requirements laid down in EEC Directive No. 89/336 relating to the suppression of radio and TV interference.
Model | Upper oven | Lower oven | Cable cross | Fuse |
section mm2 | ||||
| rating | rating | & type of the cable |
|
|
|
|
| |
|
|
|
|
|
ZBD 902 | 2870 W | 2800 W | 6 mm2 Type 6242Y | 30 A. |
|
|
|
|
|
FOR OTHER EUROPEAN COUNTRIES
Model | Upper oven | Lower oven | Cable cross | Fuse |
section mm2 | ||||
| rating | rating | & type of the cable |
|
|
|
|
| |
|
|
|
|
|
ZBD 902 | 2870 W | 2800 W | 4 mm2 HO7 | 30 A. |
|
|
|
|
|
8