![Installation](/images/new-backgrounds/78027/7802745x1.webp)
Installation
The oven must be installed according to the instructions supplied.
DIMENSIONS | Height |
| 878 mm. |
OF RECESS | Width | ||
| Depth |
| 550 mm. |
|
|
|
|
DIMENSIONS | Height |
| 320 mm. |
OF THE | Width |
| 420 mm. |
MAIN OVEN | Depth |
| 390 mm. |
CAVITY | Oven capacity | 53.2 litres | |
|
|
|
|
DIMENSIONS | Height |
| 185 mm. |
OF THE | Width |
| 420 mm. |
LOWER OVEN | Depth |
| 400 mm. |
CAVITY | Oven capacity | 31 litres | |
|
|
|
|
This oven must be installed by qualified personnel to the relevant British Standards.
Upper oven ratings
Convection element | 2.08 kW |
Convection Fan | 30 W |
Oven Light | 15 W |
Cooling Fan | 25 W |
Total Rating | 2.150 kW |
Lower oven ratings |
|
Oven element | 1.89 kW |
Top element | 0.834 kW |
Grill element | 1.82 kW |
Oven Light | 15 W |
Total Rating | 1.930 kW |
Total connected load | 4.055 kW |
Electrical Connection
The oven is designed to be connected to
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Live terminal | |||||||
Letter N | - | Neutral terminal | |||||||
|
|
|
|
|
|
| or E | - | Earth terminal |
|
|
|
| ||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must comply to the specifications given below.
For Uk use only
Connection | Min. size | Cable / flex | Fuse | ||
via | Cable/flex | type |
|
| |
|
|
|
|
|
|
• Cooker | 6 mm2 | PVC/PVC | 30 A | ||
Control |
|
| twin and |
|
|
Circuit |
|
| earth |
|
|
|
|
|
|
|
|
For Europe use only |
|
|
| ||
|
|
|
| ||
Min. size Cable/flex | Cable / flex type |
| Fuse | ||
|
|
|
|
| |
4 mm2 |
| H05 |
| 30 A | |
|
|
|
|
|
|
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should these safety measures not be carried out.