Zanussi ZDF 866 Installation, Electrical Connection, Dimensions, Of Recess, Of The, Main Oven

Models: ZDF 866

1 24
Download 24 pages 11.46 Kb
Page 23
Image 23
Installation

Installation

The oven must be installed according to the instructions supplied.

DIMENSIONS

Height

 

878 mm.

OF RECESS

Width

560-570 mm.

 

Depth

 

550 mm.

 

 

 

 

DIMENSIONS

Height

 

320 mm.

OF THE

Width

 

420 mm.

MAIN OVEN

Depth

 

390 mm.

CAVITY

Oven capacity

53.2 litres

 

 

 

 

DIMENSIONS

Height

 

185 mm.

OF THE

Width

 

420 mm.

LOWER OVEN

Depth

 

400 mm.

CAVITY

Oven capacity

31 litres

 

 

 

 

This oven must be installed by qualified personnel to the relevant British Standards.

Upper oven ratings

Convection element

2.08 kW

Convection Fan

30 W

Oven Light

15 W

Cooling Fan

25 W

Total Rating

2.150 kW

Lower oven ratings

 

Oven element

1.89 kW

Top element

0.834 kW

Grill element

1.82 kW

Oven Light

15 W

Total Rating

1.930 kW

Total connected load

4.055 kW

Electrical Connection

The oven is designed to be connected to 230-240V (50Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

Connection

Min. size

Cable / flex

Fuse

via

Cable/flex

type

 

 

 

 

 

 

 

 

• Cooker

6 mm2

PVC/PVC

30 A

Control

 

 

twin and

 

 

Circuit

 

 

earth

 

 

 

 

 

 

 

 

For Europe use only

 

 

 

 

 

 

 

Min. size Cable/flex

Cable / flex type

 

Fuse

 

 

 

 

 

4 mm2

 

H05 RR-F

 

30 A

 

 

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should these safety measures not be carried out.