Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS
Width: | 580 mm. |
Depth: | 510 mm. |
CUT OUT DIMENSIONS | |
Width: | 550 mm. |
Depth: | 470 mm. |
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
Ignition HT Spark |
| |
Spark Generator | Ispra Control's BF 50046 | |
|
| |
Spark Gap |
| Fixed |
| ||
Heat Input |
| 1.9 kW (6483 BTU/HR) |
Rapid Burner |
|
|
Heat Input | 2.9 kW Natural Gas (9895 BTU/HR) | |
|
| 2.7 kW L.P.G. (9212 BTU/HR) |
Auxiliary Burner |
| |
Heat Input |
| 1.0 kW (3412 BTU/HR) |
TYPE OF GAS | CHARACTERISTICS |
|
| BURNER | RAPID | AUXILIARY | ||||||
|
|
| (large) | (medium) | (small) | |||||||
|
|
|
|
|
|
|
|
| ||||
|
| POSITION | MAX | MIN | MAX | MIN | MAX | MIN | ||||
|
|
|
|
|
|
|
|
| ||||
|
| 3 |
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
| VALUE = 37.78 MJ/m | Ws - 50.7 MJ/ m3 |
| NOMINAL THERMAL |
|
|
|
|
|
| |
20 mbar |
| POWER kW | 2.9 | 0.65 | 1.9 | 0.45 | 1.0 | 0.33 | ||||
| NOMINAL FLOW |
|
|
|
|
|
| |||||
| RATE | m3/h | 0.276 | 0.062 | 0.181 | 0.043 | 0.095 | 0.031 | ||||
| NOZZLEREFERENCE | 119 | Adjust. | 96 | Adjust. | 70 | Adjust. | |||||
|
| 1/100 mm |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| VALUE = 49.92 MJ/Kg |
| NOMINAL THERMAL |
|
|
|
|
|
| |||
|
| POWER kW | 2.7 | 0.65 | 1.9 | 0.45 | 1.0 | 0.33 | ||||
LPG GAS |
| NOMINAL FLOW |
|
|
|
|
|
| ||||
| RATE | g/h | 195 | 46.8 | 137 | 32.4 | 72 | 23.8 | ||||
| NOZZLEREFERENCE | 86 | 40 | 71 | 32 | 50 | 28 | |||||
|
| 1/100 mm |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Burner | Dia. Tap |
| 1/100 mm |
Auxiliary | 28 |
32 | |
Rapid | 40 |
Aeration adjustment none
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
9