Instructions for the Installer
Engineers technical data
Overall dimensions
Width: | 580 mm |
Depth: | 500 mm |
Cut out dimensions
Width: | 550 mm |
Depth: | 470 mm |
Supply connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.
Rear Left Burner | (semi rapid) | |
Heat Input |
| 2.0 kW (6824 BTU/HR) |
Front Left Burner | (rapid) | |
Heat Input | 3.0 kW Natural gas (10236 BTU/HR) | |
|
| 2.8 kW L.P.G. (9554 BTU/HR) |
Rear Right Burner | (semi rapid) | |
Heat Input |
| 2.0 kW (6824 BTU/HR) |
Front Right Burner | (auxiliary) | |
Heat Input |
| 1.0 kW (3412 BTU/HR) |
TYPE OF GAS | Characteristics | BURNER |
| RAPID | AUXILIARY | |||||
|
| (large) | (medium) | (small) | ||||||
|
|
|
|
|
|
|
| |||
POSITION |
| MAX | MIN | MAX | MIN | MAX | MIN | |||
|
|
|
|
|
|
|
| |||
NATURAL GAS |
| VALUE = 37.78 MJ/m3 Ws - 50.7 MJ/ m3 | NOMINALTHERMAL |
|
|
|
|
|
| |
20 mbar | POWER | kW | 3.0 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | ||
NOMINAL FLOW |
|
|
|
|
|
|
| |||
RATE | m3/h | 0.286 | 0.062 | 0.190 | 0.043 | 0.095 | 0.031 | |||
NOZZLEREFERENCE | 119 | Adjust. | 96 | Adjust. | 70 | Adjust. | ||||
1/100 mm |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
| VALUE = 49.92 MJ/Kg | NOMINAL THERMAL |
|
|
|
|
|
| ||
LPG GAS | POWER | kW | 2.8 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | ||
NOMINAL FLOW |
|
|
|
|
|
|
| |||
RATE | g/h | 202 | 47 | 144 | 32 | 72 | 24 | |||
NOZZLEREFERENCE | 86 | 40 | 71 | 32 | 50 | 28 | ||||
1/100 mm |
|
|
|
|
|
|
|
Burner | Dia. Tap |
| 1/100 mm |
|
|
Auxiliary | 28 |
32 | |
Rapid | 40 |
APPLIANCE CLASS: | 3 |
APPLIANCE CATEGORY: | II2H3+ |
APPLIANCE GAS SUPPLY:Natural gas G20/20 mbar
Aeration adjustment none
8